PAC Project, ioProject, and FactoryFloor applications leak GDI objects on computers running Windows XP
Revision:  7.0
Published:  5/19/2008
Applies To
PAC Project Professional
PAC Project Basic
ioProject Professional Software Suite
ioProject Basic Software Suite
FactoryFloor Software
Versions

SYMPTOMS

PAC Control, ioControl, and OptoControl may crash while adding variables, renaming variables, or compiling a strategy. This may also occur when using other software suite components.

The following is an example of the error messages produced:

WORKAROUND

When using any Opto 22 version of PAC Project, ioProject, or FactoryFloor software on a computer with Windows XP Service Pack 2, or Windows XP with no Service Pack, the Desktop theme needs to be set to Windows Classic theme.

To correct the problem, do the following:

1. Right-click on an empty part of the Desktop.

2. Select Properties.

3. With the Themes tab selected, choose the Windows Classic theme, and click the OK button.

4. Restart the computer to apply this workaround.

CAUSE

This problem occurs because of a Microsoft bug with how Themes are handled in Windows XP, Service Pack 2 and with Windows XP with no Service Pack. A resource leak caused by the bug may eventually cause the Opto 22 application to crash. More information about this bug can be found on the Microsoft Help and Support Web site, KB article 319740, MFC Applications Leak GDI Objects on computers that are running Windows XP .

RESOLUTION

Windows XP Service Pack 3 corrects this issue. Refer to the Microsoft Help and Support Web site, for service pack information. Hotfix 319740 is included in this update.

Relevant Downloads
No relevant downloads have been specified.
Questions? Contact Opto 22 Product Support.
Phone: 800-835-6786 or 951-695-3080
Email: support@opto22.com

DISCLAIMER

This Opto 22 Knowledge Base ('OptoKB') article is intended to provide general technical information on a particular subject or subjects and is not an exhaustive treatment of such subjects. Accordingly, the information in this OptoKB article is not intended to constitute application, design, software, or other professional engineering advice or services. Opto 22 may modify the OptoKB articles at any time. Before making any decision or taking any action which might affect your equipment, you should consult a qualified professional.

OPTO 22 DOES NOT WARRANT THE COMPLETENESS, TIMELINESS, OR ACCURACY OF THE DATA CONTAINED IN THIS OPTOKB ARTICLE AND MAY MAKE CHANGES THERETO AT ANY TIME AT ITS SOLE DISCRETION WITHOUT NOTICE. FURTHER, ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS 'AS IS.' IN NO EVENT SHALL OPTO 22 BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIRECT, INDIRECT INCIDENTAL, CONSEQUENTIAL, LOSS PROFIT, OR DAMAGE, EVEN IF OPTO 22 HAS BEEN ADVISED ON THE POSSIBILITY OF SUCH DAMAGES.

OPTO 22 DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED WITH RESPECT TO THE INFORMATION (INCLUDING HARDWARE, SOFTWARE, AND/OR FIRMWARE) PROVIDED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTIBILITY, AND NON-INFRINGEMENT. Note that certain jurisdictions do not sanction the exclusion of implied warranties: thus, this disclaimer may not apply to you.

Copyright © 2016 Opto 22. All rights reserved.

My.Opto22

All Opto22

Request Information
  • FREE Product Brochure
  • Product Demonstration
  • PreSales Engineering Assistance

Opto 22 Product Support

Opto 22 Product Support is FREE Monday through Friday 7 a.m. to 5 p.m. Pacific Time

Product Support Numbers:

Local: (951) 695-3080
Toll-Free: (800) 835-6786
Fax: (951) 695-3017
support@opto22.com

Products

None

Downloads

None

Documents

None