KB58672
Published: October 12, 2007
Revision: 2.0

Numeric recipe table indices are reset when >2047


Applies To:

PAC Display Professional
PAC Display Basic

Versions Affected:

Problem was discovered in version: R8.0k
Problem is fixed in version: R8.1a

Resolved In Version:

Problem is fixed in version: R8.1a


Symptoms:

If an upload recipe results file with an integer or float table has more than 2048 consecutive elements, and the table is divided into more than one section (group of 2048 consecutive elements), then the indices for the sections after the first section restart at 0. The table element values are correct, but the the indices are incorrect.

Example:

An integer table is divided into 2 sections: elements 0 – 2047, and elements 2048 – 3000.

Indices 0 – 2047 are correctly listed in the results file, but indices 2048 – 3000 are listed as 0 – 952.

Sample recipe results file:

My_Control_Engine: Integer Table.My_Integer_Table
0: <value>
1: <value>
.....
2047: <value>

My_Control_Engine: Integer Table.My_Integer_Table
0: <value>/This should read: 2048: <value>
1: <value> /This should read: 2049: <value>
...
952: <value>/This should read: 2999: <value>

Resolution:

Opto 22 has resolved this issue.


Questions?

Contact: Opto 22 Product Support.
Phone: 800-835-6786 or 951-695-3080
Email: support@opto22.com


DISCLAIMER

This Opto 22 Knowledge Base ('OptoKB') article is intended to provide general technical information on a particular subject or subjects and is not an exhaustive treatment of such subjects. Accordingly, the information in this OptoKB article is not intended to constitute application, design, software, or other professional engineering advice or services. Opto 22 may modify the OptoKB articles at any time. Before making any decision or taking any action which might affect your equipment, you should consult a qualified professional.

OPTO 22 DOES NOT WARRANT THE COMPLETENESS, TIMELINESS, OR ACCURACY OF THE DATA CONTAINED IN THIS OPTOKB ARTICLE AND MAY MAKE CHANGES THERETO AT ANY TIME AT ITS SOLE DISCRETION WITHOUT NOTICE. FURTHER, ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS 'AS IS.' IN NO EVENT SHALL OPTO 22 BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIRECT, INDIRECT INCIDENTAL, CONSEQUENTIAL, LOSS PROFIT, OR DAMAGE, EVEN IF OPTO 22 HAS BEEN ADVISED ON THE POSSIBILITY OF SUCH DAMAGES.

OPTO 22 DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED WITH RESPECT TO THE INFORMATION (INCLUDING HARDWARE, SOFTWARE, AND/OR FIRMWARE) PROVIDED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTIBILITY, AND NON-INFRINGEMENT. Note that certain jurisdictions do not sanction the exclusion of implied warranties: thus, this disclaimer may not apply to you.

Copyright © 2024 Opto 22. All rights reserved.