SNAP 32-Ch -20mA to +20mA Analog Current Input Module

Production Specification

The SNAP-AIMA-32 provides 32 channels of -20 mA to +20 mA analog current input. The module does not supply loop excitation current. Although the 32 channels are not isolated from each other, the module is transformer isolated and optically isolated from other modules and devices.

Part of the SNAP PAC System, the module mounts on a SNAP PAC rack with a SNAP PAC brain or rack-mounted controller. Analog, digital, and serial I/O modules can all be on the same rack. Such an I/O unit is also well suited for PC-based control or for use as intelligent remote I/O for an Allen-Bradley Logix PLC system, such as ControlLogix, MicroLogix, or CompactLogix.

CAUTION: We strongly recommend that you use the SNAP-AIMA-HDB breakout rack and SNAP-HD-BF6 wiring harness with this module. Miswiring of any point on the module can cause severe damage; the breakout rack protects the module from many wiring errors.

Compatibility: This module can be used only with SNAP PAC brains and R-series controllers. See SNAP-AIMA for a two-channel module that can also be used with legacy SNAP Ethernet and serial brains.

For a similar module that provides two isolated channels, see SNAP-AIMA-i.

For a module that provides two isolated channels and supplies loop excitation, see SNAP-AIMA-iSRC.

Build your system in the SNAP I/O Configurator.

Input Range

-20 mA to +20 mA

Over-Range Limits

From -22 to +22 mA
(+/-20 mA range)

Resolution

0.8 microamps

Input Filtering

-3 dB @ 31 Hz

Data Freshness (Max)

1.15 s

DC Common Mode Rejection

>-120 dB

AC Common Mode Rejection

>-120 dB @ 60 Hz

Maximum Survivable Input

36 mA or 9 VDC

Maximum Operating Common Mode Voltage

250 V

Accuracy

0.1% (20 microamps)

DRIFT: Gain Temperature Coefficient

30 PPM/ °C

DRIFT: Offset Temperature Coefficient

15 PPM/ °C

Isolation

1500 V, field to logic

Power Requirements

5 VDC (±0.15 ) @ 150 mA

Input Resistance - Single Ended

100 ohms (each channel)

Operating Temperature

-20 °C to 70 °C

Storage Temperature

-40 °C to 85 °C

Humidity

5-95%, non-condensing

Torque, hold-down screws

Not to exceed 1 in-lb (0.11 N-m)

Torque, connector screws

5.22 in-lb (0.59 N-m)

Agency Approvals

UL, CE, RoHS, DFARS; UKCA.

Warranty

Lifetime

SNAP PAC System Product Guide

This document lists and describes all current Opto 22 SNAP PAC System part numbers, including PAC Project software, SNAP PAC controllers, and SNAP I/O modules of all kinds. SNAP PAC mounting racks and SNAP power supplies are also listed.

SNAP Analog Input Modules Data Sheet

SNAP I/O analog input modules are part of Opto 22's SNAP PAC System. This document includes descriptions, specifications, and wiring and dimensional diagrams for the following analog input modules:

For analog modules with channel-to-channel isolation, see Form 1182, the SNAP Isolated Analog Input Modules Data Sheet.

UKCA Declaration of Conformity (EMC, LVD, RoHS)

This document is the Manufacturer's Declaration of Conformity for the products listed herein, in accordance with the rules, regulations and standards of the United Kingdom. The models cited have been tested to the essential requirements listed in the Standards section, and fully comply with the legislation as listed in UK Legislation section.

Declaration of Conformity (EMC, LVD, RoHS)

This document is the Manufacturer's Declaration of Conformity for the products listed herein, in accordance with European, international, and/or national standards and regulations.

Case Study: Amalgamated Research, LLC

As the research and development department of Amalgamated Sugar in the 1970s, ARi began with a mission to develop efficient processes to extract sugar from sugar beets.

But over time, their continuous research in the industrial separation field has led them far beyond sugar.

Opto 22 RoHS 3 Statement of Compliance - Restriction of Hazardous Substances

This document is a statement of compliance with the EU Directive 2015/863/EU, Restriction of Hazardous Substances (RoHS 3). This document lists Opto 22 products that comply with the substance restrictions of the RoHS 3 directive.

UL Approval Document

This document lists all Opto 22 part numbers that have the Underwriters Laboratory (UL) approval.

CE Declaration: Component

This document is the Manufacturer's Declaration for the listed products as mentioned in the attachment - to which this confirmation refers - that they are in accordance with the mentioned European, international and/or national standards and regulations.

CE Declaration: EMC

This document is the Manufacturer's Declaration for the listed products as mentioned in the attachment - to which this confirmation refers - that they are in accordance with the mentioned European, international and/or national standards and regulations.

CE Declaration: Low Voltage

This document is the Manufacturer's Declaration for the listed products as mentioned in the attachment - to which this confirmation refers - that they are in accordance with the mentioned European, international and/or national standards and regulations.

CAD 3D Drawing: SNAP-AIMA-32 Analog Input Module

This CAD file contains a 3-dimensional drawing of the SNAP-AIMA-32 analog input module, which provides 32 channels of -20 mA to +20 mA analog current input.

CAD Drawing: SNAP-AIV-32, SNAP-AIMA-32

This CAD file includes drawings of the SNAP-AIV-32 and SNAP-AIMA-32 analog input modules, which each have 32 input points per module.

Video: SNAP PAC System Overview

This overview describes the four integrated components of the SNAP PAC system: software, controllers, brains and I/O. This hardware and software system is designed for industrial control, remote monitoring and data acquisition.

Video: Securing SNAP Module

A quick overview on securing a SNAP Module to a SNAP rack.

Video: Removing a SNAP Module

A quick overview on removing a SNAP module.

Accuracy vs Resolution

What's the difference between accuracy and resolution in analog I/O specifications? Try your own specs in the calculator.