SNAP PAC 16-Module Mounting Rack
$161.00 USD
Price in USA and Canada Only
Availability: In Stock
The SNAP-PAC-RCK16 mounts one SNAP PAC brain or on-the-rack controller and up to 16 analog, digital, serial, and special-purpose SNAP I/O modules. The SNAP-PAC-RCK16 can be DIN-rail or panel mounted.
This rack works with all SNAP I/O modules on the Opto 22 website. Analog, digital, and serial modules can be mixed on the rack and placed in any position. (Some serial modules are limited to a maximum of eight on one rack. See module data sheets for limitations and power requirements.)
Together with I/O modules and a brain or rack-mounted controller, this rack forms an I/O unit that provides distributed control in a SNAP PAC System. The I/O unit can also be used for PC-based control or as intelligent remote I/O for an Allen-Bradley MicroLogix PLC or other RSLogix-based system, such as ControlLogix or CompactLogix.
If you need Factory Mutual approval, see the SNAP-PAC-RCK16-FM instead.
Other SNAP PAC racks available:
NOTE: This rack replaces part number SNAP-M64. All brains that mount on a SNAP-M64 can also be mounted on this rack.
Power1 Requirements
|
5.0 to 5.2
VDC @ 4.2 Amps max
|
I/O Processor2
Compatibility
|
SNAP-PAC-R1
SNAP-PAC-R2
SNAP-PAC-EB1
SNAP-PAC-EB2
SNAP-PAC-SB1
|
SNAP-PAC-R1-FM
SNAP-PAC-R2-FM
SNAP-PAC-EB1-FM
SNAP-PAC-EB2-FM
SNAP-PAC-SB2
|
Replacement Fuse
|
SNAP-FUSE7.5AB
or Littelfuse 297 07.5
|
Rack Power Terminals
Wire Size
|
22 to 14
AWG
|
Operating Temperature
|
0 to 70
°C
|
Relative Humidity
|
95%, non-condensing
|
1 Power
requirements shown are for a rack, a processor, and a full load of analog
modules. Power requirements for SNAP serial and high-density modules
are higher. See module data sheets.
2 “I/O Processor”
means a SNAP PAC brain or SNAP PAC on-the-rack controller. For compatibility
with legacy Opto 22 products, see form #1693, Legacy and Current
Product Comparison and Compatibility Charts.
|
| 1684 |
SNAP PAC racks mount one SNAP PAC brain or on-the-rack controller, plus up to 4, 8, 12, or 16 SNAP input/output (I/O) modules. Both standard wired controllers and brains and Wired+Wireless models are mounted on these racks.
I/O modules may be analog, digital, or serial modules. All module types can be mixed together on the same rack in any position.
|
| 1569 |
|
| 1696 |
|
This CAD file includes drawings of the SNAP-PAC-RCK16, a mounting rack that holds one SNAP PAC brain or on-the-rack controller, plus up to 16 analog, digital, and serial SNAP I/O modules.
This drawing also applies to the SNAP-PAC-RCK16-FM rack, which is Factory Mutual approved.
|
This CAD file includes a drawing of the base for the SNAP-PAC-RCK16, a mounting rack that holds one SNAP PAC brain or on-the-rack controller plus any mix of up to 16analog, digital, and serial SNAP I/O modules.
This drawing also applies to the SNAP-PAC-RCK16-FM, which is Factory Mutual approved.
|