Smoothness of Analog Outputs Forum - Published: I decided to run a little test today on my test bench in my lab. I was going to test for the delay between inputting a signal and the time gets written out. Instead I found that the output signal was...moreI decided to run a little test today on my test bench in my lab. I was going to test for the delay between inputting a signal and the time gets written out. Instead I found that the output signal was choppy. My set up is thus: SNAP PAC R1 (8.4 firmware) 4 Position Rack Analog Input (AIV-8) Analog Output (AOV-25) I ran a signal generator with a sinusoidal Waveform (8V p-p, 4V offset. 0.2 HZ) and an oscilloscope on the signal generator signal and on the AOV. The program Consisted of two blocks: ...... <less Pac Control Professional Forum - Published: Hello, I work at a place which is using a SNAP-PAC-R1 firmware version 8.5c. I need to make a small change to I believe what is called a persistent variable. I literally just need to change the value...moreHello, I work at a place which is using a SNAP-PAC-R1 firmware version 8.5c. I need to make a small change to I believe what is called a persistent variable. I literally just need to change the value from the integer 4 to 2. It doesn’t seem like there is a straightforward way to do this and when I cross reference the variables I can’t see where a value is moved into the variable. I’ve looked at a couple of persistent variables and it seems like they were somehow set and then downloaded the contr...... <less When Uploading New Code - Major Failure Forum - Published: Hi, I am trying to add a GROOV Epic rack to an existing SNAP PAC Controller and i keep having this download failure that makes me revert to previous file. Screen Shot 2022-07-11 at 4.16.00 PM1012×1010 122 KB ...Hi, I am trying to add a GROOV Epic rack to an existing SNAP PAC Controller and i keep having this download failure that makes me revert to previous file. Screen Shot 2022-07-11 at 4.16.00 PM1012×1010 122 KB ... <less Which is the highest version of the S1 firmware? Forum - Published: Hello everyone! In 2008, a S1 controller was installed on site and has been running normally. The PAC control software used at that time seemed to be 8.2. The customer wants to upgrade the PAC control...moreHello everyone! In 2008, a S1 controller was installed on site and has been running normally. The PAC control software used at that time seemed to be 8.2. The customer wants to upgrade the PAC control software to 9.6. Does the S1 firmware need to be upgraded? Which is the highest version of the S1 firmware? Where can I download it? I’ve only found firmware for various smart I0s. Another question, can S1 and R1 controllers communicate with kingSCADA of wellintech (https://www.wellintech.com/)? Th...... <less A problem with R1 firmware Forum - Published: 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less PAC Display Runtime Causing Controller to Crash Forum - Published: I’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value...moreI’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value’ color and then (occasionally) change to the ‘Comm Failure’ color. The only way to recover my controller and get my strategy to start up again after this happens is to hit the reset button on the S2. The strange thing is that my controller is otherwise perfectly happy to communicate with PAC Contr...... <less Groov EPIC SetPIDMode Forum - Published: Hi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac...moreHi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac system but not on the groov epic. Can someone please assist on this? Thanks... <less Updated OptoTagPreserve Forum - Published: In case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is...moreIn case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is OptoTagPreserve? Glad you asked… OptoTagPreserve copies variables from your PAC Control strategy running on a groov EPIC processor or SNAP PAC controller and saves them in a password-protected binary file or a plain-text XML, OptoScript, or init.txt file. The primary reason you would use this u...... <less EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Pac Control Professional Forum - Published: Hello, I work at a place which is using a SNAP-PAC-R1 firmware version 8.5c. I need to make a small change to I believe what is called a persistent variable. I literally just need to change the value...moreHello, I work at a place which is using a SNAP-PAC-R1 firmware version 8.5c. I need to make a small change to I believe what is called a persistent variable. I literally just need to change the value from the integer 4 to 2. It doesn’t seem like there is a straightforward way to do this and when I cross reference the variables I can’t see where a value is moved into the variable. I’ve looked at a couple of persistent variables and it seems like they were somehow set and then downloaded the contr...... <less When Uploading New Code - Major Failure Forum - Published: Hi, I am trying to add a GROOV Epic rack to an existing SNAP PAC Controller and i keep having this download failure that makes me revert to previous file. Screen Shot 2022-07-11 at 4.16.00 PM1012×1010 122 KB ...Hi, I am trying to add a GROOV Epic rack to an existing SNAP PAC Controller and i keep having this download failure that makes me revert to previous file. Screen Shot 2022-07-11 at 4.16.00 PM1012×1010 122 KB ... <less Which is the highest version of the S1 firmware? Forum - Published: Hello everyone! In 2008, a S1 controller was installed on site and has been running normally. The PAC control software used at that time seemed to be 8.2. The customer wants to upgrade the PAC control...moreHello everyone! In 2008, a S1 controller was installed on site and has been running normally. The PAC control software used at that time seemed to be 8.2. The customer wants to upgrade the PAC control software to 9.6. Does the S1 firmware need to be upgraded? Which is the highest version of the S1 firmware? Where can I download it? I’ve only found firmware for various smart I0s. Another question, can S1 and R1 controllers communicate with kingSCADA of wellintech (https://www.wellintech.com/)? Th...... <less A problem with R1 firmware Forum - Published: 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less PAC Display Runtime Causing Controller to Crash Forum - Published: I’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value...moreI’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value’ color and then (occasionally) change to the ‘Comm Failure’ color. The only way to recover my controller and get my strategy to start up again after this happens is to hit the reset button on the S2. The strange thing is that my controller is otherwise perfectly happy to communicate with PAC Contr...... <less Groov EPIC SetPIDMode Forum - Published: Hi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac...moreHi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac system but not on the groov epic. Can someone please assist on this? Thanks... <less Updated OptoTagPreserve Forum - Published: In case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is...moreIn case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is OptoTagPreserve? Glad you asked… OptoTagPreserve copies variables from your PAC Control strategy running on a groov EPIC processor or SNAP PAC controller and saves them in a password-protected binary file or a plain-text XML, OptoScript, or init.txt file. The primary reason you would use this u...... <less EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
When Uploading New Code - Major Failure Forum - Published: Hi, I am trying to add a GROOV Epic rack to an existing SNAP PAC Controller and i keep having this download failure that makes me revert to previous file. Screen Shot 2022-07-11 at 4.16.00 PM1012×1010 122 KB ...Hi, I am trying to add a GROOV Epic rack to an existing SNAP PAC Controller and i keep having this download failure that makes me revert to previous file. Screen Shot 2022-07-11 at 4.16.00 PM1012×1010 122 KB ... <less Which is the highest version of the S1 firmware? Forum - Published: Hello everyone! In 2008, a S1 controller was installed on site and has been running normally. The PAC control software used at that time seemed to be 8.2. The customer wants to upgrade the PAC control...moreHello everyone! In 2008, a S1 controller was installed on site and has been running normally. The PAC control software used at that time seemed to be 8.2. The customer wants to upgrade the PAC control software to 9.6. Does the S1 firmware need to be upgraded? Which is the highest version of the S1 firmware? Where can I download it? I’ve only found firmware for various smart I0s. Another question, can S1 and R1 controllers communicate with kingSCADA of wellintech (https://www.wellintech.com/)? Th...... <less A problem with R1 firmware Forum - Published: 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less PAC Display Runtime Causing Controller to Crash Forum - Published: I’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value...moreI’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value’ color and then (occasionally) change to the ‘Comm Failure’ color. The only way to recover my controller and get my strategy to start up again after this happens is to hit the reset button on the S2. The strange thing is that my controller is otherwise perfectly happy to communicate with PAC Contr...... <less Groov EPIC SetPIDMode Forum - Published: Hi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac...moreHi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac system but not on the groov epic. Can someone please assist on this? Thanks... <less Updated OptoTagPreserve Forum - Published: In case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is...moreIn case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is OptoTagPreserve? Glad you asked… OptoTagPreserve copies variables from your PAC Control strategy running on a groov EPIC processor or SNAP PAC controller and saves them in a password-protected binary file or a plain-text XML, OptoScript, or init.txt file. The primary reason you would use this u...... <less EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Which is the highest version of the S1 firmware? Forum - Published: Hello everyone! In 2008, a S1 controller was installed on site and has been running normally. The PAC control software used at that time seemed to be 8.2. The customer wants to upgrade the PAC control...moreHello everyone! In 2008, a S1 controller was installed on site and has been running normally. The PAC control software used at that time seemed to be 8.2. The customer wants to upgrade the PAC control software to 9.6. Does the S1 firmware need to be upgraded? Which is the highest version of the S1 firmware? Where can I download it? I’ve only found firmware for various smart I0s. Another question, can S1 and R1 controllers communicate with kingSCADA of wellintech (https://www.wellintech.com/)? Th...... <less A problem with R1 firmware Forum - Published: 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less PAC Display Runtime Causing Controller to Crash Forum - Published: I’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value...moreI’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value’ color and then (occasionally) change to the ‘Comm Failure’ color. The only way to recover my controller and get my strategy to start up again after this happens is to hit the reset button on the S2. The strange thing is that my controller is otherwise perfectly happy to communicate with PAC Contr...... <less Groov EPIC SetPIDMode Forum - Published: Hi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac...moreHi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac system but not on the groov epic. Can someone please assist on this? Thanks... <less Updated OptoTagPreserve Forum - Published: In case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is...moreIn case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is OptoTagPreserve? Glad you asked… OptoTagPreserve copies variables from your PAC Control strategy running on a groov EPIC processor or SNAP PAC controller and saves them in a password-protected binary file or a plain-text XML, OptoScript, or init.txt file. The primary reason you would use this u...... <less EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
A problem with R1 firmware Forum - Published: 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... 微信图片_20210913155303807×605 211 KB My customer has an R1. He wants to upgrade the firmware. He doesn’t know how to operate. This happens. I’ve never seen anything like this. Excuse me, what is the reason? How to solve it?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less PAC Display Runtime Causing Controller to Crash Forum - Published: I’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value...moreI’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value’ color and then (occasionally) change to the ‘Comm Failure’ color. The only way to recover my controller and get my strategy to start up again after this happens is to hit the reset button on the S2. The strange thing is that my controller is otherwise perfectly happy to communicate with PAC Contr...... <less Groov EPIC SetPIDMode Forum - Published: Hi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac...moreHi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac system but not on the groov epic. Can someone please assist on this? Thanks... <less Updated OptoTagPreserve Forum - Published: In case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is...moreIn case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is OptoTagPreserve? Glad you asked… OptoTagPreserve copies variables from your PAC Control strategy running on a groov EPIC processor or SNAP PAC controller and saves them in a password-protected binary file or a plain-text XML, OptoScript, or init.txt file. The primary reason you would use this u...... <less EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less PAC Display Runtime Causing Controller to Crash Forum - Published: I’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value...moreI’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value’ color and then (occasionally) change to the ‘Comm Failure’ color. The only way to recover my controller and get my strategy to start up again after this happens is to hit the reset button on the S2. The strange thing is that my controller is otherwise perfectly happy to communicate with PAC Contr...... <less Groov EPIC SetPIDMode Forum - Published: Hi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac...moreHi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac system but not on the groov epic. Can someone please assist on this? Thanks... <less Updated OptoTagPreserve Forum - Published: In case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is...moreIn case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is OptoTagPreserve? Glad you asked… OptoTagPreserve copies variables from your PAC Control strategy running on a groov EPIC processor or SNAP PAC controller and saves them in a password-protected binary file or a plain-text XML, OptoScript, or init.txt file. The primary reason you would use this u...... <less EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
PAC Display Runtime Causing Controller to Crash Forum - Published: I’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value...moreI’m having a very strange problem with the PAC Display Pro runtime and my PAC-S2 controller. Shortly after I start the runtime and things begin to load, my graphics will change to the ‘Last Known Value’ color and then (occasionally) change to the ‘Comm Failure’ color. The only way to recover my controller and get my strategy to start up again after this happens is to hit the reset button on the S2. The strange thing is that my controller is otherwise perfectly happy to communicate with PAC Contr...... <less Groov EPIC SetPIDMode Forum - Published: Hi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac...moreHi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac system but not on the groov epic. Can someone please assist on this? Thanks... <less Updated OptoTagPreserve Forum - Published: In case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is...moreIn case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is OptoTagPreserve? Glad you asked… OptoTagPreserve copies variables from your PAC Control strategy running on a groov EPIC processor or SNAP PAC controller and saves them in a password-protected binary file or a plain-text XML, OptoScript, or init.txt file. The primary reason you would use this u...... <less EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Groov EPIC SetPIDMode Forum - Published: Hi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac...moreHi, I am facing difficulties with “setpidmode” under Groov EPIC controller. I am using “setpidmode(xxx, 0) when i was trying to change that particular PID to auto mode. It was working fine on snap pac system but not on the groov epic. Can someone please assist on this? Thanks... <less Updated OptoTagPreserve Forum - Published: In case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is...moreIn case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is OptoTagPreserve? Glad you asked… OptoTagPreserve copies variables from your PAC Control strategy running on a groov EPIC processor or SNAP PAC controller and saves them in a password-protected binary file or a plain-text XML, OptoScript, or init.txt file. The primary reason you would use this u...... <less EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Updated OptoTagPreserve Forum - Published: In case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is...moreIn case you missed it, just a heads up that OptoTagPreserve has been updated and is available for download on our website; https://www.opto22.com/support/resources-tools/downloads/optotagpreserve What is OptoTagPreserve? Glad you asked… OptoTagPreserve copies variables from your PAC Control strategy running on a groov EPIC processor or SNAP PAC controller and saves them in a password-protected binary file or a plain-text XML, OptoScript, or init.txt file. The primary reason you would use this u...... <less EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
EB1 missing Ethernet2 Forum - Published: I went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the...moreI went to go configure Ethernet2 and found it is missing from the list in Pac Manager Status Read. Any hints? Can ETH2 be disabled? My current firmware is listed below. I’m getting ready to load the latest firmware to see if that does anything. 0xFFFF F030 0018 Loader Version R1.0d 0xFFFF F030 0000 Memory Map Version 1 0xFFFF F030 0230 Current Boot Device Flash Memory 0xFFFF F030 001C Firmware Version ...... <less I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
I/O point silmultanioiusly on & off? Forum - Published: I have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well...moreI have a strategy running in Pac Control 9.6 (on an R2) and a strategy running in 10.3 (on an Epic groov) The I/O in question is located on the snap pac rack and the Epic is looking at it as well. The snap pac sees the point as off (correct) and the Epic sees it as on (wrong). What is going on here? io issue1586×672 42.3 KB ... <less Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Obtain a list of all tags using .net applications Forum - Published: Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?...Hi All, Is there a way to obtain a list of tag names, and preferably types, using Controller SDK in a VB.NET Application ?... <less PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
PAC Control cannot communicate with EPIC Forum - Published: Hi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For...moreHi, I am trying to read some IOs from an EPIC Controller from a SnapPac controller and i am getting a communication error. I’ve done this process before, and have always worked for other devices. For some reason on this one, i can’t make it work. Screenshot 2022-11-02 at 9.50.47 AM1180×394 63.3 KB ... <less Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Monitor SNAP S2 with groov AR-1 Forum - Published: I would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i...moreI would like to monitor the status of whether or not a SNAP controller is running. Specifically if it goes down for whatever reason, such as a power outage, I want the groov to send me an email which i can then use to text a phone. What would be the best method to do this?... <less Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Wrong analog in value reading in PAC disply Forum - Published: we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby...we are facing problem with our SNAP-PAC-R1 analog reading in PAC disply showing 110 psi with 4ma signal.Please advise how to resolve this issue. Joby... <less Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Profi DP Slave Forum - Published: Dear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC...moreDear Sir I want to communicate with Siemens 315-2DP module via profibus, but i am not getting the DP slave program of opto22.can you please guide me how test the communication between these two PLC through profibus, similarly when i was configuring the opto as a DP master, only Profibus Polling chart is running remaing charts are in stop mode..can you please guide me how to solve the situation in both the cases (opto as a DP master as well as DP slave).(also provide me the programs for DP s...... <less REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
REST reading /device/strategy/vars/int64s not working Forum - Published: I get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s...moreI get no results when calling http://10.10.26.54/api/v1/device/strategy/vars/int64s But if I query a specific variable there are results. http://10.10.26.54/api/v1/device/strategy/vars/int64s/nLine1Position {“value”:2169743} I’m on firmware version R9.5d... <less SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
SNAP-PAC-EB2 compatible with SNAP-UP1-ADS? Forum - Published: in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(...in 1693 Current and Legacy Product Charts, page 4, it says SNAP-PAC-EB2 is not compatible with SNAP-UP1-ADS in 1688 SNAP PAC System Migration Tech_Note, page 17, it says SNAP-PAC-EB2 is compatible with SNAP-UP1-ADS seem to be another error:(... <less Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Message read from ControlLogix Forum - Published: I am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix...moreI am curious if there is a way to perform a message read from a ControlLogix PLC to an Opto snap-up1-ads. Currently there are ~32 analog inputs wired to the up1-ads that I need to get into the Logix PLC. I do not have the program file(s) for the up1-ads, but I am able to see the configured point names through ioManager / Inspect I/O Unit. Is there a way to set up a message instruction in the ControlLogix to read this data? What worries me is the firmware appears to be quite outdated: 0xFFFF F030...... <less Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Cirrus Ignition Driver Docs need help Forum - Published: The Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode >...moreThe Cirrus docs need a good review from someone at Opto - they give bad info: At the bottom of this page: https://docs.chariot.io/display/CLD/Scanning+Specific+Tags Start PAC Control Debug mode (Mode > Debug) and clear the controller’s RAM (Control Engine > Clear RAM). WARNING: Clearing the controller’s RAM will remove all persistent values in the controller’s memory. If the strategy has other persistent variables, you may want to archive it (File > Archive Strategy) before continuing. Emphasis ...... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
RESTful feature Forum - Published: Hello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should...moreHello! I upgraded my S1 PAC controller to firmware 9.5, and tested the RESTful feature. I can read the data in the PAC through the IE. Excuse me, can I write data through the IE to S1 PAC? What should we do if we can do it? Like this, “” https://10.10.10.2/api/v1/device/strategy/vars/int32s/pump_count"". Thanks. zhang... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Epic PR-1 (no I/O) with Snap EB1 remotes comm loss Forum - Published: I have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all...moreI have a small development system with 1 PR-1 (no I/O) and 3 EB1 I/O racks. All device ethernet connections are home runs to the network switch. In testing, if I disconnect one rack comm is lost to all racks and PR-1. Re-connection starts all comm. Have I missed something in the PR-1 configuration? Any suggestions would be appreciated, Sheldon... <less Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Whats New in Pac Project 10.5 Forum - Published: Hi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted...moreHi Ya Forum Fans. Heads up! There is a new version of PAC Project out. Typically, a point release has some bug fixes and perhaps a new feature or two. But this one packs enough of a punch that I wanted to bring its new goodies to your attention. In fact, many of you here have been asking for a few of these new features! Please note!! There are new features in this release that require firmware versions that are not released yet. In this forum post, I will simply make note with a ** The required ...... <less « PreviousPage 2 of 8Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items