EPIC and SNAP Serial Module Forum - Published: Can we use the EPIC to control the serial modules on a SNAP-PAC controller or the PAC Brain?...Can we use the EPIC to control the serial modules on a SNAP-PAC controller or the PAC Brain?... <less Help with a SNAP-AOV-25 module Forum - Published: I am using the SNAP-AOV-25 to give a 0 - 5 VDC output to a thyristor for a heater control. I have used a SNAP-AOV-5 previously to do this job but the current project needed to use only 1 rack because of...moreI am using the SNAP-AOV-25 to give a 0 - 5 VDC output to a thyristor for a heater control. I have used a SNAP-AOV-5 previously to do this job but the current project needed to use only 1 rack because of space limitations. The SNAP-AOV-5 is working fine with no problems at all, however the SNAP-AOV-25 is not working as I expected. The 5 VDC supply to the AOV-25 is the same configuration as the AOV-5, in other words it is looped through the +ve terminal on the module (terminal 2) and out (terminal...... <less Changing SNAP I/O Modules Forum - Published: Is it necessary to turn power off to the EB1 brain when changing a SNAP i/o module? Is it necessary to restart the strategy on a PAC-S1 after changing a SNAP i/o module on a rack that uses a EB1 brain? Thanks...Is it necessary to turn power off to the EB1 brain when changing a SNAP i/o module? Is it necessary to restart the strategy on a PAC-S1 after changing a SNAP i/o module on a rack that uses a EB1 brain? Thanks... <less Read back Snap output modules Forum - Published: I’m a new user to Snap I/O. When I write to an Analog output module to set an analog value, can I then read the Output value back to make sure the the output is set to the value I requested ? I am...moreI’m a new user to Snap I/O. When I write to an Analog output module to set an analog value, can I then read the Output value back to make sure the the output is set to the value I requested ? I am checking for a fault in the output circuit… Perhaps the module failed or something attached to the output is preventing the output from reaching its goal. If we can’t read back from the output module, then I can add an additional analog input to the output to verify the output compliance. I would rathe...... <less Using snap modules without the rack Forum - Published: Hello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very...moreHello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very interested in doing. According to that document, I can communicate with analog modules using either ARCNET on pins 12(+) and 14(-) or using RS-485 on pins 9(+) and 11(-). For testing, I have a USB-RS485 converted attached to my PC and will communicate with the modules using a VB.net application....... <less Snap Pac Analog Module in Pac Control Strategy Forum - Published: Hi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac...moreHi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac Control but it does not let me change it. In Pac Manager it does let me select it as a 4-20mA type. How can I assure that I will measure 4-20mA sensors correctly? Captura de pantalla 2024-08-22 1201281497×554 167 KB Captura de pantalla 2024-08-22 120157490×838 70.5 KB Captura de pantalla 2024-08-2...... <less Can SNAP PAC system auto detect I/O modules? - old forum post Forum - Published: nvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O...morenvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O modules upon they are plugged (hot plug)? Can PAC Manager or PAC control diagnostic the status of I/O Modules? - to see whether it still works or break few channels. - to see Quality of I/O signals … Report 11-08-2007, 5:34 PM kdowney Joined on 05-10-2007 Opto 22 Posts 28 R...... <less Ignition 8.3 SNAP PAC module? Forum - Published: Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?...Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?... <less Mixing loop-powered and externally powered sensors on SNAP-AIMA-iSRC module Forum - Published: I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you....I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you.... <less Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Help with a SNAP-AOV-25 module Forum - Published: I am using the SNAP-AOV-25 to give a 0 - 5 VDC output to a thyristor for a heater control. I have used a SNAP-AOV-5 previously to do this job but the current project needed to use only 1 rack because of...moreI am using the SNAP-AOV-25 to give a 0 - 5 VDC output to a thyristor for a heater control. I have used a SNAP-AOV-5 previously to do this job but the current project needed to use only 1 rack because of space limitations. The SNAP-AOV-5 is working fine with no problems at all, however the SNAP-AOV-25 is not working as I expected. The 5 VDC supply to the AOV-25 is the same configuration as the AOV-5, in other words it is looped through the +ve terminal on the module (terminal 2) and out (terminal...... <less Changing SNAP I/O Modules Forum - Published: Is it necessary to turn power off to the EB1 brain when changing a SNAP i/o module? Is it necessary to restart the strategy on a PAC-S1 after changing a SNAP i/o module on a rack that uses a EB1 brain? Thanks...Is it necessary to turn power off to the EB1 brain when changing a SNAP i/o module? Is it necessary to restart the strategy on a PAC-S1 after changing a SNAP i/o module on a rack that uses a EB1 brain? Thanks... <less Read back Snap output modules Forum - Published: I’m a new user to Snap I/O. When I write to an Analog output module to set an analog value, can I then read the Output value back to make sure the the output is set to the value I requested ? I am...moreI’m a new user to Snap I/O. When I write to an Analog output module to set an analog value, can I then read the Output value back to make sure the the output is set to the value I requested ? I am checking for a fault in the output circuit… Perhaps the module failed or something attached to the output is preventing the output from reaching its goal. If we can’t read back from the output module, then I can add an additional analog input to the output to verify the output compliance. I would rathe...... <less Using snap modules without the rack Forum - Published: Hello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very...moreHello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very interested in doing. According to that document, I can communicate with analog modules using either ARCNET on pins 12(+) and 14(-) or using RS-485 on pins 9(+) and 11(-). For testing, I have a USB-RS485 converted attached to my PC and will communicate with the modules using a VB.net application....... <less Snap Pac Analog Module in Pac Control Strategy Forum - Published: Hi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac...moreHi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac Control but it does not let me change it. In Pac Manager it does let me select it as a 4-20mA type. How can I assure that I will measure 4-20mA sensors correctly? Captura de pantalla 2024-08-22 1201281497×554 167 KB Captura de pantalla 2024-08-22 120157490×838 70.5 KB Captura de pantalla 2024-08-2...... <less Can SNAP PAC system auto detect I/O modules? - old forum post Forum - Published: nvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O...morenvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O modules upon they are plugged (hot plug)? Can PAC Manager or PAC control diagnostic the status of I/O Modules? - to see whether it still works or break few channels. - to see Quality of I/O signals … Report 11-08-2007, 5:34 PM kdowney Joined on 05-10-2007 Opto 22 Posts 28 R...... <less Ignition 8.3 SNAP PAC module? Forum - Published: Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?...Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?... <less Mixing loop-powered and externally powered sensors on SNAP-AIMA-iSRC module Forum - Published: I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you....I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you.... <less Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Changing SNAP I/O Modules Forum - Published: Is it necessary to turn power off to the EB1 brain when changing a SNAP i/o module? Is it necessary to restart the strategy on a PAC-S1 after changing a SNAP i/o module on a rack that uses a EB1 brain? Thanks...Is it necessary to turn power off to the EB1 brain when changing a SNAP i/o module? Is it necessary to restart the strategy on a PAC-S1 after changing a SNAP i/o module on a rack that uses a EB1 brain? Thanks... <less Read back Snap output modules Forum - Published: I’m a new user to Snap I/O. When I write to an Analog output module to set an analog value, can I then read the Output value back to make sure the the output is set to the value I requested ? I am...moreI’m a new user to Snap I/O. When I write to an Analog output module to set an analog value, can I then read the Output value back to make sure the the output is set to the value I requested ? I am checking for a fault in the output circuit… Perhaps the module failed or something attached to the output is preventing the output from reaching its goal. If we can’t read back from the output module, then I can add an additional analog input to the output to verify the output compliance. I would rathe...... <less Using snap modules without the rack Forum - Published: Hello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very...moreHello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very interested in doing. According to that document, I can communicate with analog modules using either ARCNET on pins 12(+) and 14(-) or using RS-485 on pins 9(+) and 11(-). For testing, I have a USB-RS485 converted attached to my PC and will communicate with the modules using a VB.net application....... <less Snap Pac Analog Module in Pac Control Strategy Forum - Published: Hi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac...moreHi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac Control but it does not let me change it. In Pac Manager it does let me select it as a 4-20mA type. How can I assure that I will measure 4-20mA sensors correctly? Captura de pantalla 2024-08-22 1201281497×554 167 KB Captura de pantalla 2024-08-22 120157490×838 70.5 KB Captura de pantalla 2024-08-2...... <less Can SNAP PAC system auto detect I/O modules? - old forum post Forum - Published: nvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O...morenvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O modules upon they are plugged (hot plug)? Can PAC Manager or PAC control diagnostic the status of I/O Modules? - to see whether it still works or break few channels. - to see Quality of I/O signals … Report 11-08-2007, 5:34 PM kdowney Joined on 05-10-2007 Opto 22 Posts 28 R...... <less Ignition 8.3 SNAP PAC module? Forum - Published: Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?...Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?... <less Mixing loop-powered and externally powered sensors on SNAP-AIMA-iSRC module Forum - Published: I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you....I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you.... <less Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Read back Snap output modules Forum - Published: I’m a new user to Snap I/O. When I write to an Analog output module to set an analog value, can I then read the Output value back to make sure the the output is set to the value I requested ? I am...moreI’m a new user to Snap I/O. When I write to an Analog output module to set an analog value, can I then read the Output value back to make sure the the output is set to the value I requested ? I am checking for a fault in the output circuit… Perhaps the module failed or something attached to the output is preventing the output from reaching its goal. If we can’t read back from the output module, then I can add an additional analog input to the output to verify the output compliance. I would rathe...... <less Using snap modules without the rack Forum - Published: Hello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very...moreHello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very interested in doing. According to that document, I can communicate with analog modules using either ARCNET on pins 12(+) and 14(-) or using RS-485 on pins 9(+) and 11(-). For testing, I have a USB-RS485 converted attached to my PC and will communicate with the modules using a VB.net application....... <less Snap Pac Analog Module in Pac Control Strategy Forum - Published: Hi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac...moreHi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac Control but it does not let me change it. In Pac Manager it does let me select it as a 4-20mA type. How can I assure that I will measure 4-20mA sensors correctly? Captura de pantalla 2024-08-22 1201281497×554 167 KB Captura de pantalla 2024-08-22 120157490×838 70.5 KB Captura de pantalla 2024-08-2...... <less Can SNAP PAC system auto detect I/O modules? - old forum post Forum - Published: nvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O...morenvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O modules upon they are plugged (hot plug)? Can PAC Manager or PAC control diagnostic the status of I/O Modules? - to see whether it still works or break few channels. - to see Quality of I/O signals … Report 11-08-2007, 5:34 PM kdowney Joined on 05-10-2007 Opto 22 Posts 28 R...... <less Ignition 8.3 SNAP PAC module? Forum - Published: Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?...Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?... <less Mixing loop-powered and externally powered sensors on SNAP-AIMA-iSRC module Forum - Published: I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you....I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you.... <less Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Using snap modules without the rack Forum - Published: Hello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very...moreHello, I use your Snap line in our OEM controller, and I came across your Module Integration Guide (form 0876-100610 dated June 2010). Communicating directly with snap modules is something that I am very interested in doing. According to that document, I can communicate with analog modules using either ARCNET on pins 12(+) and 14(-) or using RS-485 on pins 9(+) and 11(-). For testing, I have a USB-RS485 converted attached to my PC and will communicate with the modules using a VB.net application....... <less Snap Pac Analog Module in Pac Control Strategy Forum - Published: Hi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac...moreHi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac Control but it does not let me change it. In Pac Manager it does let me select it as a 4-20mA type. How can I assure that I will measure 4-20mA sensors correctly? Captura de pantalla 2024-08-22 1201281497×554 167 KB Captura de pantalla 2024-08-22 120157490×838 70.5 KB Captura de pantalla 2024-08-2...... <less Can SNAP PAC system auto detect I/O modules? - old forum post Forum - Published: nvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O...morenvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O modules upon they are plugged (hot plug)? Can PAC Manager or PAC control diagnostic the status of I/O Modules? - to see whether it still works or break few channels. - to see Quality of I/O signals … Report 11-08-2007, 5:34 PM kdowney Joined on 05-10-2007 Opto 22 Posts 28 R...... <less Ignition 8.3 SNAP PAC module? Forum - Published: Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?...Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?... <less Mixing loop-powered and externally powered sensors on SNAP-AIMA-iSRC module Forum - Published: I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you....I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you.... <less Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Snap Pac Analog Module in Pac Control Strategy Forum - Published: Hi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac...moreHi guys, I am running my strategy in an EPIC Controller and I am also using a Snap Pac with a EB2 Brain as an IO Point. I am trying to configure the analog modules of the Snap Pac as 4-20mA type in Pac Control but it does not let me change it. In Pac Manager it does let me select it as a 4-20mA type. How can I assure that I will measure 4-20mA sensors correctly? Captura de pantalla 2024-08-22 1201281497×554 167 KB Captura de pantalla 2024-08-22 120157490×838 70.5 KB Captura de pantalla 2024-08-2...... <less Can SNAP PAC system auto detect I/O modules? - old forum post Forum - Published: nvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O...morenvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O modules upon they are plugged (hot plug)? Can PAC Manager or PAC control diagnostic the status of I/O Modules? - to see whether it still works or break few channels. - to see Quality of I/O signals … Report 11-08-2007, 5:34 PM kdowney Joined on 05-10-2007 Opto 22 Posts 28 R...... <less Ignition 8.3 SNAP PAC module? Forum - Published: Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?...Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?... <less Mixing loop-powered and externally powered sensors on SNAP-AIMA-iSRC module Forum - Published: I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you....I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you.... <less Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Can SNAP PAC system auto detect I/O modules? - old forum post Forum - Published: nvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O...morenvl Joined on 07-12-2007 Posts 19 Can SNAP PAC system auto detect I/O modules? Our customers ask the questions regarding I/O modules: Do PAC controller R-series & Brain automatically detect the I/O modules upon they are plugged (hot plug)? Can PAC Manager or PAC control diagnostic the status of I/O Modules? - to see whether it still works or break few channels. - to see Quality of I/O signals … Report 11-08-2007, 5:34 PM kdowney Joined on 05-10-2007 Opto 22 Posts 28 R...... <less Ignition 8.3 SNAP PAC module? Forum - Published: Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?...Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?... <less Mixing loop-powered and externally powered sensors on SNAP-AIMA-iSRC module Forum - Published: I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you....I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you.... <less Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Ignition 8.3 SNAP PAC module? Forum - Published: Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?...Surprised to learn that this module hasn’t been made available for 8.3. Any ETA on that?... <less Mixing loop-powered and externally powered sensors on SNAP-AIMA-iSRC module Forum - Published: I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you....I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you.... <less Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Mixing loop-powered and externally powered sensors on SNAP-AIMA-iSRC module Forum - Published: I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you....I have two sensors that I want to connect to a SNAP-AIMA-iSRC module; one is loop powered and the other is externally powered with its own power supply. Is this possible? Thank you.... <less Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Snap-IAC5 Module as Tank Probe Sensor Forum - Published: I don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and...moreI don’t know if I am the only one who’s ever considered doing this (and quit laughing), but really it work like a champ. The IAC5 has a impedance of 169k ohms which at first I thought would too high and might not work. Connecting 120 vac to terminal 1 on the module and then terminal 2 to a tank probe which is immersed produces right at 660 micoAmps current flow which is probably not enough to give you a shock (maybe a tickle). Just make sure that the probe common is connected to neutral and w...... <less SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP-OMR6 vs SNAP-ODC5R. Mechanical relay ouput modules Forum - Published: It still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22...moreIt still surprises me how many people work with Opto 22 hardware and software and yet are not signed up to OptoNews and so miss out on hearing all the cool stuff that happens in the world of Opto 22… Another topic for another day perhaps, right now I just want to answer a question about our new digital output modules which got announced in[URL=“http://www.opto22.com/site/optonews/2011/optonews_08312011.aspx”] last week’s OptoNews. SNAP-OMR6. 4 channels of 6 amp mechanical relay goodness, more th...... <less I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module Forum - Published: Hi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I...moreHi all, I have couple of a normally close solenoid, that is connected directly to SNAP-OAC5 module. one of those solenoids is constantly getting 120 VAC when it’s off and 120 VAC when they are on, I tested the other ones, and they are getting 0 VAC when they are OFF and get 120 VAC when they are on. I replaced the module and put a new one on and same problem resisted, where I’m getting 120 either it’s off or on. Any idea what could cause this problem?... <less SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP Profibus Module Forum - Published: I have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I...moreI have a question about the Profibus module. We have a customer who would like our system to communicate with a Siemens S7 300 PLC. They want to send us a setpoint and want us to send back data. I believe we can use Ethernet (TCP/IP) or possibly Profibus with the PROFI module. I’m sure the S7 will be the network master. Can the PROFI module operate as a slave? I plan on using an R2 controller. Thanks. Joey... <less SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP-AOVA-8 module and its SNAP-HD-20F6 cable Forum - Published: I am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and...moreI am setting up a new system that has some of the AOVA-8 output modules installed. I look forward to using this module based on it’s apparent versatility. I have the corresponding, required cables and just want to comment about this combination. I think the excitation voltage for this module should be separated from the outputs. With the premade cable, all of the flying leads come out together. Logically the outputs will land at a row of terminals going to my field devices. Excitation voltag...... <less SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP-SCM-SSI Module and Novotechnik TP1 Forum - Published: Ok, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for...moreOk, I just successfully connected and got working an SSI module and Novotechnik magnostrictive linear sensor. I am bringing this up because I had to struggle a bit but once you know what to look for it is fairly straightforward. Also I wanted to point out just how accurate this thing is and how fast it is for the money. I purchased this Novotechnik 24" long sensor with SSI interface for around $300 and and reads in absolute postion to to 1 micrometer (0.000039"), and is accurate to around 13 m...... <less Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Communicating with SDM120ct-mv power analyzer through Modbus using the Snap SCM-485-422 module Forum - Published: Hello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that...moreHello all! I am quite new to the world of Opto22 and Modbus, I have been learning it for 3 weeks now and so far, I understand most of the basics. Now I have a task that has been assigned to me and that is to gather the data on my sdm120ct-mv power analyzer and read that data on my PC through Pac control. I have been using the Opto22 Modbus Master kit to try and communicate with my energy meter but so far, I have been getting an error -216 in the n04AsFloatStatus. I just want to read the Data on ...... <less 125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
125-300VDC Card or Epic Module? Forum - Published: Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?...Does opto22 make a SNAP card or Epic Module that can handle 125-300VDC?... <less Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Debounce for snap counter Forum - Published: Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?...Is there a way to add a debounce to a snap pac i/o counter (the module’s built-in counter function)?... <less SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNMP I/O point OID's? Forum - Published: I have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac...moreI have made numerous exhaustive searches here on these forums as well as internet searches, and have found no information on this, thus this post. The equipment and software I’m using: Opto22 Snap Pac R2 0 Snap IDC5-SW 1 Snap IDC5-SW 2 Snap IDC5-SW 3 Snap ODC5R 4 Snap ODC5R 5 Snap ODC5R 6 Snap OMR6-C 7 Snap AIV-4 8 Snap SCM-485-422 (This will vary from site to site as required by the equipment present.) Opto22 MIB file (v2) Burk ArcPlus Touch remote control with SNMP Plus module Burk AutoLoad re...... <less Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Raspberry Pi and SNAP? Forum - Published: Hello! Any chance there will be an official product for using an rpi with SNAP modules?...Hello! Any chance there will be an official product for using an rpi with SNAP modules?... <less RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
RS232/485 Serial C++ Example Code Forum - Published: Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks....Hello, is there any example code how to read/write on a RS232 or RS485 module based on the “C++ OptoMMP Software Development Kit for SNAP PAC” code? We have SNAP-SCM-232 and SNAP-SCM-485-422 modules. Thanks.... <less Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Humidity Sensor Forum - Published: Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ...Is there a way that I can use this Humidity Sensor with a SNAP Module? bourns.com error 122.07 KB ... <less Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Get the EPIC DI/DO module state in PAC Control Forum - Published: The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?...The PAC Control can use the Get HDD Module Status command to move the state of the SNAP HDD module to an integer variable. So how do we move a EPIC DI/DO module state to an integer variable?... <less Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Modbus Master & Slave Communication Forum - Published: Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?...Hello everyone, I would like to know if it is possible to use both TCP Modbus Master communication on a SNAP PAC R2 PLC and Modbus serial slave communication on a communication module SNAP-SCM 485 ?... <less 4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
4-20 loop sourcing external vs local Forum - Published: Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?...Is there a thread discussing the wiring of snap pac AI modules in regards to where the source voltage is introduced?... <less Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Loose Modules (PAC) Forum - Published: Spent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules ...moreSpent most of today troubleshooting QNAN errors on various I/O modules. We mostly saw them with SNAP-AITM-4i modules, but also had the problem with SNAP-OMR6T-C and a couple others. Then other modules (in Point Config in PAC Manager) would show up as AITM-4i modules! Then other EMPTY slots would show up as AITM-4i modules! It was mayhem. (FYI, using SNAP-PAC-RCK-16 with EB1 and EB2 brains – I saw same problem on two racks.) After doing lots of unplugging and plugging modules back in to see if we...... <less I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
I/O Screw size? Forum - Published: What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…...What is the screw size of the snap-pac I/O modules? A whole bunch were never installed and subsequently lost…... <less Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Old SNAP-AITM screws Forum - Published: Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost....Older SNAP-AITM modules (circa 2010) had four Philips screws for the field wiring (new modules (and really old modules) had/have captive screws). What size are these old screws? One was lost.... <less AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
AICTD Conversion Forum - Published: When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?...When converting a Snap-PAC system over to EPIC hardware are there any modules that would work for the ICTD sensors?... <less Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Problem with 1678 Modbus/TCP Protocol Guide Forum - Published: I have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG...moreI have found what appears to me to be an error on Page 29 of the Modbus/TCP Protocol Guide in the Analog Module Address Table. This pertains to the values used for both the CONFIG POINT and CONFIG FEATURE. For reference: I am using a SNAP-PAC-EB1 brain with firmware R8.5e on a SNAP-PAC-RCK12 and have been experimenting by moving a SNAP-AIMA 2 channel module around to different positions along with some input and output modules. According to the table each module position has 128 registers reserv...... <less Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Use SNA-AIV-4 as 4 to 20 mA input Forum - Published: Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?...Hi I have a SNAP-AIV-4 module, can it be used with a 4 to 20 mA sensor by placing a 220 ohm resistor in parallel to one of the channels?... <less SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP-IDC-16 and SNAP-IDC-HT-16 Forum - Published: Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!...Excuse me, what is the difference between SNAP-IDC-16 and SNAP-IDC-HT-16? Can you give me an example of the application of the two modules? thank you!... <less SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP AIMA-8 & SNAP-AILC with pressure transmitters and load cells Forum - Published: Just some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I...moreJust some clarifying questions. If I have three the same type of pressure transmitters that I am using for my project I only need one SNAP AIMA-8 controller since it has 8 channels. Am I correct? I also have two load cells and I am using the SNAP-AILC module for those. I ssume I will need two seperate modules for each load cell. Is this correct? Thanks for your patience... <less Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Reading SNAP-AIMA-i from CODESYS via Modbus Forum - Published: I have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA ...moreI have a SNAP PAC R1 controller running a strategy that includes two scaled inputs from a SNAP-AIMA-i module in channel 3 on the rack. In the PAC Control strategy, the inputs are scaled such that 4 mA = 0 and 20 mA = 100. I need to leave the PAC Control strategy alone, but I would like to read the unscaled mA from the two inputs on this module. I checked the Modbus TCP Protocol Guide and saw that the a SNAP 2-Ch Analog Input in the third channel on a rack uses registers 25 and 26 (first input) a...... <less SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP-AIRTD QNAN problem Forum - Published: Dear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It...moreDear all! I maintain a SNAP PAC system, and I get from some SNAP-AIRTD module IVAL and XVAL value: “-1.#QNAN”. This values periodically change from the normal field value and back to “-1.#QNAN”. It happens almost every second. The field specialist didn’t find any problem in the loops and in the power supply of the rack. He tried to restart the rack, but the problem didn’t solve. I attached a picture of the IO Unit. The problem is on the module 8 to 12. QNAN.jpg700×560 56.2 KB Many thanks for a...... <less Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Factory Mutual Approvals? Forum - Published: Dear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However,...moreDear Opto, I’m a big fan of the SNAP-AIMA-8 module because it’s relatively high density, but you can still connect directly to the screw terminals on the module without using a breakout board. However, we’re installing a panel that needs to be compliant with Class I Div 2, and it appears that only the AIMA-4 and AIMA-32-FM are FM approved. It seems to me that the electronics inside the AIMA-8 would not be so different from those inside the other two modules. What would it take to get an AIMA-8 m...... <less -QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
-QNAN on Inputs Forum - Published: I am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2...moreI am using a SNAP-OAC-EB2 with 12 analog input modules in a 16 slot rack. Each of the input modules has 8 analog inputs. I am measuring temperature with this system. Every once in a while (about 1-2 times per week), all of the inputs into one module will produce a “-QNAN” for about 2 to 3 minutes, then resume working correctly. This has occurred on several different modules. Whenever it happens, it affects all 8 inputs into the module. Anyone have any clues as to what might be causing this? The ...... <less PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
PR1 GRV-OMRIS-8 Start On Pulse Forum - Published: Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?...Is Start On Pulse supported on a OMRIS-8? I have a strategy trying to use it and the output does nothing. The command help only shows support on SNAP modules, so maybe this command never made it to EPIC?... <less PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
PID to control SSR through Mechanical Relay module Forum - Published: I have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use...moreI have a SNAP-PAC-R1 system that has several modules including SNAP-OMR6T-C and a SNAP-AOVA-8. I would like to power a submersible heater by cycling it off and on in a PID loop. I was hoping to use the output from one of those modules to trigger a OPTO22 240D45 to then cycle it off and on. It doesn’t look like I can use the output of the OMR6T-C as an output to the PID controller. My thinking was that an on off of the relay module would turn the SSR which would then allow it to control a 2...... <less SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP Multi-Channel I/O Confusion - old forum post Forum - Published: Robertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point...moreRobertson Joined on 06-23-2007 Posts 6 SNAP Multi-Channel I/O Confusion Just started working with the SNAP Multi-Channel I/O. One of the first things that jumps out at me is that in the point configuration the module channels are identified 0-3 (4-channels). On the module itself the wiring diagram identifies the channels 0-3. However, the red lights that show the I/O status are identified 1-4. Shouldn’t we stick with the 0-3 pattern? Craig Report 05-30-2008, 1:40 AM gmitchell Joined on 12-0...... <less What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
What type of CAN module use? Forum - Published: Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman....Hi everyone, I’m looking for people that could help me better understanding CAN module, For what kind of use should we use SNAP-SCM-CAN2B and SNAP-SCM-232 ? Cordially Roman.... <less Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Pb16h Forum - Published: I would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the...moreI would like to control an existing PB16H digital board with a [SIZE=2]SNAP-ODC-32-SNK digital output module using the [/SIZE][SIZE=2]SNAPHD-G4F6 [/SIZE][SIZE=2]header cable. The data sheet for the snk module states it will work with a G4PB16H but doesn’t list the PB16H as a possiblility. Since the G4PB16H and PB16H will accept the same brains (currently it is a B1 brain), I assume it will work. Anyone know if this will work. [/SIZE] Thanks... <less I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
I/O expansion past one rack? Forum - Published: How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)...How is I/O expanded past one rack using Epic I/O without adding another Epic controller? Specifically the Digital AC modules? (I like the higher density vs. SnapPAC modules)... <less IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
IDC32 Module Intermittently Losing Communication Forum - Published: We recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was...moreWe recently replaced the control panel on a machine, but kept the software basically the same. The only change was moving the I/O tags to fit the new SNAP-PAC module layout. Part of this change was moving points from an old IDC-16 module to an IDC32 module. We’re having an issue where every few hours the IDC32 module seemingly drops its communication with the R1 controller, causing all inputs that are ON to register as OFF for anywhere from 200 ms to 1 second. Every time this happens, the “times...... <less B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
B3000 Identify Optomux Type response Forum - Published: I have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how...moreI have no SNAP analog modules to test so I want to know how the B3000 responds to this command. Mine responds with A00 digital type. If one address contains both digital and analog SNAP modules, how does it respond? It seems likely that digital and analog modules could be located at different consecutive addresses if this makes the Identify Optomux Type response more meaningful.... <less Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Ignition with older Mistic controllers Forum - Published: I have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that...moreI have a project coming up where a plant wants to integrate its HMI’s and tag data into Ignition. However, some of the controllers are from the Mistic family. I know that Cirrus Link has a module that will pull tag data from Groov Epics and Snap Pac controllers but is there a way to get data from the Mistic protocol? Would I have to pass tag data from the Mistic controller to a Snap Pac or Groov then pull the tags from there? Thanks... <less Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Alternative to the adapter cable for high density IO modules? Forum - Published: Hello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is...moreHello everyone, I’m new to the Opto SNAP system and automation control in general. As I become more familiar with the SNAP system and my machine in which I’m adding the SNAP system my imagination is taking off with all the sensors I can add and control I can support. This led me to look at the higher channel density modules and I was surprised (disappointed) to see the 16 and 32 channel modules require a cable. It’s not so much the cost (although it’s expensive) as the awkward nature of an in...... <less Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Lightning Strike Protection (SNAP-AILC) Forum - Published: Good Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect”...moreGood Morning, I am using a SNAP PAC Rack with a load cell module (SNAP-AILC) to monitor the weight on a very large outdoor conveyor scale. The unit we are replacing has a “lightning strike disconnect” puck in between the 4-20mA transmitter and the old input module connected to the controller. This is necessary because the system is a very large metal plant that is outside during storms and has a history of being struck by lightning. We are eliminating the 4-20mA transmitter and using a 6 lead ...... <less SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SSR connection with a Digital Output I/O module Forum - Published: Hello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and...moreHello all, I am a student in a laboratory, new to the system. We have a machine I want to implement a PID heating system. I have understood the software side but hardware. I use SNAP-ODC5A-I module and connect to SSR unit. I have realized I cannot get 5V DC from I/O module to activate the SSR unit. Instead I measure ~5 mV with multimeter. How can I do a proper connection, do I miss a point? Thank you very much! H... <less Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Comm options for B100 brain Forum - Published: Customer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can...moreCustomer currently has an S2 talking to a B100 using one of the onboard serial ports. Between the two is a fiber link (serial-fiber-serial). They need to co-opt the fiber for an Ethernet run. So can I install a EB-rack with a SNAP serial module at the other end of the new fiber Ethernet run to talk to the B100? Don’t see how to set that up in PAC Project.... <less Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Limitations of R1 with serial number lower than 600,000 Forum - Published: We’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs...moreWe’ve got a number of R1 controllers that are old enough to have serial numbers below 600,000. According to the user guide: “SNAP-PAC-R1s with serial numbers lower than 600,000, and all SNAP-PAC-R1-Bs, are limited to eight 4-channel digital modules per rack; the remaining eight can be analog, serial, and high-density digital modules.” In the case of the R1-Bs, they mount to a “B series” rack. And a limitation of the B Series racks is that 4-channel digital modules must be mounted on one end of...... <less Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Suggestions for Accessing Expanded Memory Mapped Areas Forum - Published: All, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input...moreAll, Please bear with me (newbie). I’ve run into something I think a number of you must have encountered at some point - typically I’ve used SNAP I/O modules with 4 points or less. I have an input module (AITM-8) with 8 inputs from which I need to read 6. The code I have is only accessing the first 4 points. I’ve since read doc 1465 (MMP Protocol Guide) and talked with support and it’s obvious that I have to access the expanded memory area but the question is how to really do this. We compile Op...... <less "Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
"Tune" your Load Cell module Forum - Published: Hi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In...moreHi All, For those of you using load cell modules (Opto 22 offers the: SNAP-AILC and SNAP-AILC-2), here’s a little short cut you can use to find your ideal Fast Settle Level and Filter Weight values. In the PAC Control Commands Help for “Set Analog Load Cell Fast Settle Level” I read the 6 steps it gives for checking out how the module does Fast Settle, which included setting up a PAC Display supertrend. But PAC Control’s built-in PID graphing tool (to “View PID Loop”) also makes a lovely little ...... <less SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP B3000 ENET Ethernet IO C++ Programming Code Problem Forum - Published: Dear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port...moreDear Sir: I am new to the OPTO22 system and I am evaluating your product on behalf of my company. My problem is that I can't designate "module zero - point zero" to be a designated output port. I am using a SNAP B3000 ENET brain that is mounted on the SNAP B8MC printed circuit board. My code can compile, however, my port never becomes a designated output port. This condition is observed in the IO manager program. The IO manager program tell me that that "module zero - point zero"...... <less Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Using SNMP to clear counter Forum - Published: The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)...The goal is to remotely clear a counter Data Point module on SNAP-B3000-ENET brain Is it possible using SNMP to do the equivalent of OptoScript functions: ClearCounter(on_point) the_count = GetClearCounter(from_point)... <less -539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
-539 I/O error; performing retry Forum - Published: SNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last...moreSNAP PAC EB2 brain is returning -539 in the controller message queue. image1163×623 364 KB The brain is only referenced in two block2 and runs ~100 msecs between blocks and ~10 msecs after the last block before the first is read again. image1274×733 26.8 KB image1274×733 27.9 KB Power is good. SNAP-PAC-EB2 brain has been replaced. Ethernet cable has been replaced. Any ideas? Does this error relate to communication with the SNAP-PAC-EB2 brain or is there an issue with a module on the SNAP-PAC-EB2...... <less Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Snap IDC5Q quadrature Forum - Published: Dear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning...moreDear I hope you are well. I came here to ask for your help, I work with the opto 22 snap pac controller, I use a hard court module, These modules are already 5 years old but over time they are burning as you can see on Photograph. The power, therefore, comes from a 5-volt source, but the GND is connected to other GNDs from other sources. the question is whether the burn could be due to the connection of the GNDs?... <less My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
My totalizer is off by app. 2000 or 3000 lbs most of the time Forum - Published: The software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some...moreThe software is Snap Pac Pro, the controller is a SNAP-PAC-S1 and the brain where the Analog module resides is an EB1. The signal comes from a new Emerson Mass flow meter that checks out good. For some reason after loading out a railcar the weight of the car is off by app. 2000 or 3000 lbs. We load 194000 lbs. at a rate of about 1200 lbs/min. Is there a problem with my script or could there be issues with communications between the Controller and Brain? The sample was going negative at startup s...... <less Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Decoding memory map module information Forum - Published: Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?...Reading module information from the Memory Map (0xF010000, 0xF0100004). Would it be possible to get the “SNAP Analog Inputs” table on pages 18-25 from 1465_OptoMMP_Protocol_Guide in an Excel spreadsheet format?... <less Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Communication SNAP-SCM-232 Forum - Published: Dear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication...moreDear all, We like to communicate with a new device by using a SNAP-SCM-232 module, this is complete new for us and there for I look for some help in how to configure and how to set up the communication. the software we use is Snap Project prof. 9.6. Our hardware setup is, controller S2 is connected to two racks both with a R1 controller, on the first rack we have installed the SNAP-SCM-232 module this is connected to the device. Who can help me on setting up the configuration and provide us with...... <less Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Using SNAP-TEX-FB16-H with SNAP-IAC-16 Forum - Published: I want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app...moreI want to use the SNAP-TEX-FB16-H breakout board in conjunction with a SNAP-IAC-16 module to monitor 120VAC inputs. I cannot seem to figure out how to wire the breakout board (I have looked at the app note, but it wasn’t of help for this board). I would like to be able to use the LEDs as input indicators when there is power being applied to the terminal. Is this possible, or is the FB16-H simply a terminal strip for inputs? Best Regards, Adam... <less Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Switching 10+ amp 120VAC loads - what am I missing? Forum - Published: Hello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights,...moreHello, My PAC/PLC experience is incredibly limited to one machine we have at work. I’m a geek though and have wanted to use a PAC system in my home shop to control all sorts of things: exterior lights, well pumps, heaters, etc. All high volt (i.e. 120 or 240 single phase), 10amp and higher circuits. I’ve reviewed the SNAP IO modules and don’t see any appropriate modules for switching these types of loads. This makes me think I’m missing a piece of the puzzle or the solution. I’ve thought maybe c...... <less Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Lost connection to an R1 through Ignition with the Cirrus module Forum - Published: Hey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module...moreHey guys, I’m running 3.4.4 of the Cirrus Opto 22 SNAP PAC driver with Ignition 7.9.8, and a couple of weeks ago it just shows not connected, and it won’t reconnect. I’ve restarted the module, reinstalled the module, restarted the gateway, and restarted the controller, and had Ignition try to connect to a new Opto 22 controller, both PAC R1, and another EPIC PR1, they are not connecting. We have not updated the Cirrus module or the Ignition gateway within the last year, so not sure why it would ...... <less If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
If I switch to another page, will the trend graph continue to record data? Forum - Published: Hello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters...moreHello, I have two questions. 1, in Groov Server for win, there is a trend map in a page. If I switch to another page, will the trend graph continue to record data? 2, can the communication parameters of the SNAP-SCM-485 module be modified in the program with commands? Baud rate, start stop and other parameters. I’m using PAC Control Pro 9.6+R1+Groov Server for win R3.4b Thank you... <less Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Remote data logging for a water treatment application. - old forum post Forum - Published: mpiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor...morempiotro Joined on 05-02-2008 Posts 1 remote data logging for a water treatment application Hi, I’m looking into setting up a basic remote monitoring/data logging system. Inputs I would need to monitor are pH, conductivity, and flow rate. I’m thinking of the snap pac system, but I have a few questions, namely: Why is there a controller module and a “brains” module? Would I require both? I would like the ability to display data at the site; something simple like an lcd text screen. Can I get a 3r...... <less Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Configuring a I/O module Forum - Published: Hello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have...moreHello everyone, I’m working on project based on an OPTO 22 snap-up1-ads, this project is already built and configured, I just have to make it work again. The problem is that one of the modules I have conected to the Opto was giving no signal, it is an analog output module (4-20 mA) but on PACManager it is configured as a Digital Input Module. I add a picture of the configuration info. Is there a way I can change this configuration manually? Thanks for your attention.... <less Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Snap-Pac-EB2 Firmware Question Forum - Published: I am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a...moreI am replacing a Snap-Pac-EB2 with a replacement in kind, and I cannot get it to work with my application. The only difference I can see is my old module had an older firmware version. Is there a place I can get older firmware files, and if so, would I be able to flash the unit with the older firmware? Thank you. The firmware version I am looking for is 200.3f... <less SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP-ODC-32-SRC to SNAP-UDC-HDB Ribbon Cable Alternative Forum - Published: My goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC...moreMy goal is to have the SNAP-UDC-HDB near the SNAP-ODC-32-SRC module, within 6" -12" inside the same electrical enclosure. Opto 22 sells the cables at 6ft lengths, this works great when you have the PAC Rack separated from the SNAP-UDC-HDB at that distance. I researched for an alternate method of connecting them. Turns out that a 40 pin hard drive cable works! I purchased 12" length cables for $6 each. Note the cable must have pin 20 open, not filled in for it to work. Attached is how I connected...... <less GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
GRV-IDC-24 with sinking output Forum - Published: We are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using...moreWe are upgrading from G4 and SNAP generations of hardware to Groov. Our next step is moving 20 rectifiers in which 10 of those have a power and fault outputs (input to Groov). We were thinking of using an GRV-IDC-24 module since they all share a common power source. The issue is that the rectifiers use a sinking (power comes through negative wire) output and were wondering if anyone know if we can still use the IDC-24 without issue?... <less Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Modbus Adress from otg file Forum - Published: Hello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my...moreHello Dear Forum in my .net application i’m accessing SNAP pack EB1 thought modbus since i will have a lot of migration to do, i whiling to make a tool to import acquisition rack configuration to my app using otg file. for DIN and DOUT there is the module and channel number that allow me to guess modbus adress but not for AIN/OUT so my question is there a way to guess analogic modbus adresse from and otg file? or is there a better way ? Best regards... <less Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Assigning IP Address Forum - Published: Hello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center...moreHello everyone, I’m trying to connect between SNAP-PAC-R1 and my PC . I’ve already installed PAC Manager and connected between the SNAP PAC and my PC using the network cable in the Learning center Package. Also i did all instructions in the module but when to assign an IP Address, The MAC address of the Brain can’t be seen. I searched a lot and read the user guide many times but can’t find any solution. So can any one help me with that ? Thanks in advance.... <less PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
PAC Motion Control Forum - Published: Hi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our...moreHi I’m looking at utilising the SNAP-PAC-MCH16 Motion Control module and the accompanying 4 x SNAP-SCM-BB4 Breakout Boards to control 16 x 48V stepper motors. I’ve not used these modules before in our previous PAC systems so I was hoping to pick at the brains trust here and see if anyone had some further info or willingness to share some tips and tricks before I order some parts to play with. Taking a single stepper motor channel on 1 of the 4 channel Breakout Boards as an example, the “1673_Mot...... <less Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Profibus Module Forum - Published: I am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and...moreI am having a problem using the Profibus module SNAP-SCMProfi. I find that for some reason the comms with this Kollmorgen drive will not initialize correctly even if I restart the power up chart, and go all the way through the Profibus initialization chart. If it does communicate it has some kind of error that prevents it from talking correctly to the drive, or most likely it will not communicate at all. I was wondering if there is anything I can do to reboot the module via memory map instead o...... <less Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Configure SNAP SCM-232 serial communications from vb.net Forum - Published: Long story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded...moreLong story short, I haven’t had any luck finding information about how to set up the serial port options (e.g. Baud Rate, Parity, etc.) of a serial module (SNAP SCM-232) through vb.net. I downloaded the “PAC Serial Module” vb example, and sometimes it communicates and sometimes it doesn’t. The devices I am trying to communicate with have different communications settings than the standard settings of the opto module. I have to set up the port options through the Pac Manager (9.6) software befo...... <less Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Two issues that need to be addressed Forum - Published: Two issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX...moreTwo issues that need to be addressed I would like to use a high density DI module, channel isolation, I chose the SNAP-IDC16. I first selected the Breakout is SNAP-TEX-FB16-L. but found that SNAP-TEX-FB16-L is not a channel isolation Is there a channel isolated Breakout for SNAP-IDC16? Also, I remember someone here to discuss the issue of network control sound and light alarm, who knows the manufacturers and models,I need an alarm that can be controlled by the network(TCP). Please tell me the i...... <less Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Redundant SNAP-PAC-S1 Forum - Published: Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval...Hi Can we configure 2 SNAP-PAC-S1 Modules as a redundant controller in which 1 will be active and 1 will react as stand by and the standby will take command when active went offline or BAD. Regards, Milind Raval... <less SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SNAP-PAC-R1 firmware upgradation failed Forum - Published: Hi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called...moreHi all. I am using SNAP-PAC-R1 controller for my application. I tried to update the firmware of the module to R9.5h via Ethernet. During firmware downloading process suddenly an error called insufficient flash memory occurred. From then module is not responding. I tried to reset and restore. But no use. Please help me to resolve the issue and make my R1 to running state. Present situation is very worst. STAT LED blinks twice after power up and then it will goes OFF. No response from controller.... <less Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Analog rate of change - old forum post Forum - Published: dsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software...moredsandstrom@pipesys.com Joined on 10-16-2007 Posts 1 Rate-of-Change for Analog Input I have a SNAP-AITM thermocouple module with a SNAP-UP1-ADS brain, SNAP-PAC-S1 controller, and PACControl Pro software. I’m looking for an elegant way to measure/record the rate of temperature change on the TC. I currently use a chart with a 1-second delay. Since that delay is not reliable in terms of repeatability, I use a Get Seconds command and then subtract the old value from the new and calculate the rate. An...... <less PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
PAC Sim Forum - Published: I’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here...moreI’m a total beginner at Opto 22 and I tried to use the simulator. The error message said that I need to register the control engine in my computer…!!! I can’t even get out of the starting blocks here…Anybody got the dummy start-up tips for using the simulator without a SNAP-PAC-R2 module connected to the computer?... <less Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Problem with iPAC Forum - Published: I have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la...moreI have the next configuration from PAC Control Basic 9.2 optocontrol.png856×607 35.9 KB there are a module SNAP-AITM-8 with 4 K thermocuples and 1 scable input. When I read it from iPAC I get: la foto(1).PNG640×960 58 KB iPAC doesn’t detect te thermocuples as Analog Input, iPAC detects it as digital input: la foto(2).PNG640×960 52.3 KB la foto.PNG640×960 79.1 KB ... <less Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Snap-idc5 within a relay circuit Forum - Published: Hello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts...moreHello I have a circuit consisting of an emergency stop button, a SNAP-IDC5, a reset button and a relay coil with a resistance of 600ohm. The circuit is powered by 24v DC supply. The SNAP-IDC5 acts simply as an indication that the Emergency Stop button circuit is healthy. The 24V supply goes through the E Stop button and then through the OPTO module and on to the reset button and then onto a relay coil which energises contacts off the relay. When the reset button is pressed to energise the relay ...... <less Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Correct way to scale a resistance input? Forum - Published: Newbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor...moreNewbie here… For my first learning project, I’ve interfaced a Davis Instruments anemometer and wind vane to, respectively, a SNAP-AIRATE card, and a SNAP AIR40K card. Also A Hydreon RG11 rain sensor configured as a 0.001" per tip tipping bucket rain gauge emulator. The anny is a magnetic sensor that “closes” once per rev of the wind cups. The direction is a 20K continuous turn pot. Everything works and I can see the raw values change in a watch window in PAC Control. (The tach module might not ...... <less Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Any PID + TPO users out there? Forum - Published: Hi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what...moreHi All, I’ve just been looking at some options for having a digital TPO as the output of PID, and am wondering if/how/where all you OptoForum users out there might be doing this. For example, what controllers/brains do you have in the mix? Do you use a SNAP-AOD-29 module or a digital output configured as a TPO? Any/all examples and details you can share will be helpful to me. Thanks! Mary... <less Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Opto 22 SNAP PAC power supply and UPS recommendations Forum - Published: We’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto...moreWe’ve had some issues recently with brown-outs and power cuts and were wondering if Opto 22 has a recommended solution for providing UPS power to SNAP PAC controllers and brains. We have multiple Opto systems, with a typical setup comprising of a SNAP-PAC-S1 controller and 4 SNAP-PAC-EB2 16 module brains. We’ve also been having issues due to voltage drift and powering multiple racks with a single 3rd-party power supply and (after reading the 1271 tech notes) are considering switching to separate...... <less Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Disable and force digital output (XVAL) from PacDisplay Forum - Published: Hi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid...moreHi, I would like to know if it is possible to perform an HMI with pacDisplay which deactivates the communication of a SNAP-ODC5-iFM output module and force the signal in the XVAL to a 24VDC solenoid. This idea is to not manipulate the PACControl, disabling the communication and forcing the digital output in the XVAL. What I can do? I appreciate any response... <less G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
G3 coating or "marine approval" Forum - Published: Hi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We...moreHi All, We had a question about G3 coating or “marine approval” so I thought I’d share the answer here in case others might be interested: “Our modules do not have G3 coating and no Marine approval. We do have some customers that have Marine approval on their complete system, which a part of the system is SNAP systems. Individually it does not have Marine approval.” -OptoMary... <less SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
SSI Module Configuration Forum - Published: I have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length...moreI have an SSI Module and an SSI rotary encoder connected to a SNAP PAC R1. I am having some issues getting it all to work. My configuration is as follows Data Bits: 20 Error Bits: 3 Data Frame Length: 23 Recommended Baud Rate: 400kHz Clock Divider: 50 Monoflop Time: 20 us Data Delay: 8 Data Bits in Frame: 20 Error Bit Offset: 21 High indicates Error Encoding: Gray Enable Scanning: Enabled I am likely missing something or misunderstanding something. In PAC Manager I see some data but it does not ...... <less Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Groov EPIC Load Cell Input Module Forum - Published: What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22...What features would you like to see an a groov EPIC Load Cell input module? Would the specs/functionality of the SNAP-AILC-2 be sufficient or are there other features you’d like to see? Your input/feedback is appreciated. Thanks, Arun Opto 22... <less Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Analog Input Unstable Forum - Published: Hi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a...moreHi All, Just what to throw this question out there to see if what I am experiencing is normal for this product. I need to read some 4-20 mA pressure transducers, so I have a SNAP-PAC AIMA-8 I/O and a SNAP-PAC-R1 Controller. The scaling of my transducer is 0 to 30000 psi. I am finding that the readings are “noisey” and jump around. So to diagnose I disconnected all the wiring from the module and hooked up a 4-20 mA calibrator to Channel 0. With the calibrator set to 4 mA the reading in PAC Ma...... <less Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Probe control Forum - Published: For those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I...moreFor those of you who have always assumed that in order to control a tank system with probes you have to have something like a B&W probe system to monitor the water levels, I have news for you. I recently refurbed the control on a booster station and well site where there were two probe systems on two tanks. The probe system controller was bad so since this was an emergency call out, I decided to try something I had been wondering about. It turns out that the Snap-IAC5 module is custom made for s...... <less PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
PACSIM 8.5c - Can it read from and write to an actual SNAP-PAC EB1 I/O rack? Forum - Published: I need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question...moreI need to test out a new Strategy using PAC SIM as I do not have a Physical controller available. I have a SNAP PAC EB1 with several I/O modules that will be installed at a customer site. My Question is… Can I actually control EB-1 I/O when my Strategy is running on PAC SIM? Since PAC SIM is using the Loop back IP adress (127.0.0.1), is it able to talk to an EB-1 that has an IP address of say for an example, 192.168.1.50 and My PC’s NIC card is set to 192.168.1.25? Thanks.... <less Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Definition of TPO? Forum - Published: Good Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output...moreGood Morning All, Can someone please explain definition of TPO as it relates to a “DIGITAL OUTPUT” in OPTO world? Digital point should simply be On/Off. Shouldn’t it? How does “Time Propotional Output” factor in to a digital point? [SIZE=2]I read form 1144-120531 but could not find any information on the subject. Module in question is an “SNAP-OAC5MA” and TPO is a configuration option for the channel (point). Thanks [/SIZE]... <less Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Control a Tower Pro SG92R Servo Motor Forum - Published: Good day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a...moreGood day to all! I am trying to control the direction of a mini servo motor for a robot arm project. I saw some posts here in the forums that the TPO is one way of Opto22’s PWM generation. I am using a Digital Output module (SNAP-ODC5SRC) to control the signal line of the servo motor. After I set up the TPO period and TPO percent I noticed that when I debug the flowchart and run the strategy the servo motor arm does not move. My knowledge on PAC Control is quite still limited so any form of idea...... <less Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Integrating third party equipment using Modbus Forum - Published: I don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a...moreI don’t know the best place to start, so… I have a piece of equipment from a vendor (large blower from EBM) that has Modbus capability. I have a SNAP-PAC-R1 controller on a 16 position rack and have a SNAP-SCM-485-422 module in one of the locations. I have downloaded and started to play with the Modbus integration kit. The blower requires Modbus RTU communication, 19200 baud rate, even parity, 1 stop bit, and 8 data bits. As I said, I have tried playing with the Modbus integration kit settings b...... <less With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
With PROFIBUS DP communication interface Forum - Published: Several converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP...moreSeveral converters are equipped with PROFIBUS DP communication interface. I use the R1 controller. What is a good way to get the operation parameters of the converter through this interface? Use SNAP-SCM-485 module? But there is no communication protocol.... <less Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Cold Junction Compensation Forum - Published: Anyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples...moreAnyone else seeing thermcouple readings in the hot junction affected by changes in ambient temperature in the cold junction? I am using a SNAP-PAC-R1 with the SNAP-AITM-4i module with 4 thermocouples connected to a high temperature application. I have noticed that changes in room temperature have an effect on the thermocouple readings, especially if the changes are drastic. For example, opening the door for a few hours during a cold winter day will have an effect on the readings. We made a cove...... <less Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Variable Rounding Issue Forum - Published: I’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position...moreI’m totally stumped here. A little background info: I am using a SNAP-SCM-ST2 module to control a stepper motor. My goal is to be able to control the position of the motor. Since I know the position I want (# of pulses) and speed that I want (freq, delta freq, time slice), I have calculated the time that the motor needs to run in order to reach the desired position and set a downtimer to that time. I have 3 time variables, timea which is the time for the motor to accelerate to its max freque...... <less Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Groov EPIC-PR1 - Restful API Forum - Published: Hey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense...moreHey Guys, I might be missing it, but is there no restful api for the EPIC-PR1 like the snap-pac-r1/r2? I know that we can build a similar function like it through node-red, but wouldn’t it make sense just to have it baked in as well? Saves a lot of work and testing. I am using a mixture of PR1 & R2’s, mainly because I need reliable serial comms for modbus RTU. Once the serial module is ready for the PR1, I will be swapping a lot and changing future builds. It would be nice to use my curren...... <less Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Moving a Point in a High Density Module Forum - Published: Another probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade...moreAnother probably dumb question after some explanation: BTW: We are currently running 9.4 basic, but will be upgrading to 9.6 Pro when we are stable enough to differentiate issues related to the upgrade from other system issues. We made an error on a PCB and 3 signals got mixed up. In the Strategy, they are read by a 32 input module SNAP-IDC-32N. Location D5 was “Not Used”. I moved the Point at D7 to D5, freeing D7. I moved the Point at D6 to D7, freeing D6. D6 is connected to a sensor, but we ar...... <less High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
High Density equivalent of GetIoUnitAsBinaryValue Forum - Published: We have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine...moreWe have re-implemented our embedded OPTO22 systems using high density modules. In the past, using only 4 input or output modules, we used GetIoUnitAsBinaryValue or GetIoUnitAsBinaryValue64 to determine the value of all inputs or outputs within each IO unit. However, we are now also using SNAP-ODC-32-SRC and SNAP- IDC-32N modules and I cannot find the equivalent command to get their entire status as a single 32 or 64 bit word. The manual states that the GetIoUnitAsBinaryValue does not work for hi...... <less Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Groov RIO with Ignition Edge Compute Module Forum - Published: We have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We...moreWe have 2 Groove RIOs running Ignition edge Compute licenses. They are on separate networks with hardwired analog 4-20ma signals running between them (to keep networks physically isolated). We purchased the ignition Edge compute license to be able to map I/O point tags to other controllers in Ignition Edge on each device. It appears that the Cirrus Link SnapPAC module that is needed to access the RIO device I/O points is a separate license from the Ignition Edge compute license? Is there another...... <less URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
URGENT - Use Two Controller with I/oMistic Forum - Published: Hello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller...moreHello, I will wish to use 2 SNAP-PAC controllers with I / O modules Mistic. they use the same configuration. pac controller number 1, uses a strategy with chart and controlle i / o pac controller number 2, uses a strategy without any chart. then I see the status of I / O in both Pac? How to configure both controller?... <less PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
PID loop on GROOV Forum - Published: Hi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in...moreHi all, Could you please provide help/documentation regarding PID loop implementation on a GROOV EPIC, with AI and AO modules using PAC Control? Any examples that could help? Is this control in relation with the processor firmware version? Is it different from PID on SNAP? Thx.... <less Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Really Long Delay (28s) Getting Data Out with SNAP-SCM-CAN2b Forum - Published: Hi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled)...moreHi All, I am suffering a problem with a SNAP-SCM-CAN2b module we have installed. It receives data and has no errors (including status LEDs) and the data is well formed (i.e. not scrambled or garbled) the problem is that the data has a 28 second delay. I got this delay by comparing the data arrival time to the data coming through a separate CAN bus USB adapter. I suspect I have misconfigured something, perhaps related to the buffering in the CAN bus reader but I can’t work out what that is. Maybe...... <less Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Keyence LR-W500 Sensor to SNAP-IDC5? Forum - Published: I’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into...moreI’m hoping somebody may be able to help out a total noob on the hardware side of things… My company recently purchased a Keyence LR-W500 sensor. As far as I can tell, I should be able to wire it into a SNAP-IDC5 input module, but I know very little about wiring. I would be eternally grateful if somebody could point me in the right direction. The LR-W500 can be configured wither NPN or PNP. I’m not sure which option is best. Here’s the extent of the wiring diagram that came in the instructions: ...... <less Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Setpoint from PAC Display to comm handle Forum - Published: Hello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus...moreHello, I am new to programming strings and RS232. I have recently put a SNAP-SCM-ST2 module into my system to run some stepper motors. I am able to put the example in from OPTO Form 1944, nStatus = TransmitReceiveString(">SetPulseFrequency(50000)", comScmStPort1, sReturn); and was able to create a program to run the motors at set speed. Now I am trying to figure out the easiest way to be able to put in a setpoint from Pac display basic to change the frequency in the TransmitReceiveString (). Tha...... <less Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Snap odc5r, snap pac r2, rck16 Forum - Published: Dear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a...moreDear Sir: Can you please point me to literature that will tell me how to correctly test the SNAP ODC5R with a DMM (digital multimeter)? The ODC5R is sitting on a RCK16 and is being controlled by a PAC R2. From the literature that I have observed, there is no schematic diagram that characterizes this module. If there is literature available can anyone point me to this literature. I am trying to see if the unit is damaged or not. If no literature is available, can you tell me how to set the ODC...... <less I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
I Figured This out: Mistic controller connected to Genesis HMI Forum - Published: Anyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic...moreAnyone ever have an arcnet communication issue with “new” noise? Our HMI is having strange characters pop up and communication seems slow or not working at times. We have been upgrading our Mistic controllers to snap pac controllers and then we use PAC control and Display for interface. I was just hoping to figure this out and to delay the upgrade for a while longer. Thanks, Kelly THE ANSWER WAS THAT ONE OF THE G4 POWER REGULATOR MODULES HAD A BLOWN FUSE. This cause all kind of noise on the ...... <less Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Encoder issue with IDC5Q Forum - Published: Hi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager...moreHi, I’m using a 5000 PPR X4 type encoder with an IDC5Q module and Snap-Pac-R1 controller. The problem is that I could only read negative counts in both directions when monitoring from Pac manager Digital bank. One direction counts fast and the other counts slower but both accumulating negative counts. The same program has been successfully used on more than 30 machines but with 500 PPR encoders. This time is a 5000 PPR X4 encoder, but the IDC5Q is able to pickup up to 25K, so it shouldn’t be a p...... <less Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Use Terminal app (PuTTY) to communicate to R1 Serial Port 0? Forum - Published: Hey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms...moreHey! I have an RS-232 device (I know…) connected to the Serial port 0 on the SNAP-PAC-R1 controller, and I’m having trouble (I know!) getting it to communicate to PAC Control. I’ve done serial comms a billion times before, and I’m using code that used to work when they had this device connected to a SNAP-SCM-232 module, so it should work. In the past, I’ve had success bypassing the Opto serial code and figuring out the communication using a Terminal program. I used to use HyperTerminal, and now ...... <less AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
AIR400K Scaling Issues Forum - Published: Hi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module...moreHi guys! Would like to get some input from everyone. I have a SNAP-AIR400K-8 which connects to Resistance output NTC Thermistors with a range of 510.06Ohms - 96,974Ohms. I’ve got the AIR400K-8 module configured to 0-100k Ohms and configured the scaling in actual vs the scaled. 510.06Ohms (120degC) and 96,974Ohms (-20degC). Problem is I’m not getting the proper equivalent. I’m getting the proper resistance readings (via multitester) and the resistance value is spot on to our reference (old temper...... <less Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Accessing older chart files Forum - Published: Hi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this...moreHi, I’m completely new to this and just started with my company, so please excuse my ignorance! We have a legacy product which was running under “Factory Floor”. My mission is to upgrade this product to upgrade to new SNAP PAC modules and port these old strategies/charts to work with the new PAC’s. I’m not sure what version these were written in - they have file extensions of “.cht” and if I try opening them in PAC Control Basic (free version) they are unrecognized. Is there a way to determin...... <less Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Newbie Question regarding EB2s Forum - Published: Appologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on...moreAppologies for newbie things but I have to start somewhere. I’ve got a 4 module rack with an EB2 connected to a power supply (SNAP-PS5). Also the latest PAC Manager interface code 9.2. I’m running on a Dell Inspiron 5520 with Windows 7 64 bit. I’m attempting to determine what state the EB2 is in (don’t know if it has an IP established or not) Here’s my questions: Should I be trying to interface directly from my network interface card with the EB2 (ethernet 1 on the card)? I’m keeping the conne...... <less Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Output frequency - old forum post Forum - Published: darryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does...moredarryl.cox@asu.edu Joined on 03-18-2008 Posts 1 Output Frequency Newbie here; Currently I have some analog and communication modules on my Snap-PAC-R2. I’m looking to output a 450Hz signal. Does anyone know how this can be done? thx DC Report 04-01-2008, 1:58 AM gmitchell Joined on 12-01-2003 Optomation Systems, Madrid, Spain Posts 153 Re: Output Frequency Although only available under PACControl Professional version (not Basic version ) you may like to take a look at the PACControl instruction ...... <less StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
StartOnPulse on PAC R1 Forum - Published: I’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the...moreI’m having something strange happening with the StartOnPulse command. I have 4 PAC-R1 controllers running the same program and two of them the StartOnPulse works correctly but on the other two the output just flashes once rapidly. I have it set for 3 seconds. The output is on a SNAP-ODC-32-SRC. All 4 controllers have the same modules in the same positions. the instruction is only used twice in the program and I verified it’s not running the second one right after the first. The output is only us...... <less Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Modbus CHNT DDSU666 power meter Forum - Published: Hello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I...moreHello all! Good day everyone! I have here a power meter that is kind of strange when it comes to its Modbus parameters (or maybe I am doing it wrong). Its name is CHNT DDSU666 power meter, may I kindly ask for some guidance regarding on Modbus for this instrument. I will attach a manual for this specific meter since it is hard to get one. I am using PAC Control to communicate with this meter and an Opto22 Learning Center with SNAP SCM 485-422 module. P.S I am apparently unable to attach a PDF fi...... <less #QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
#QNAN on all wired analog inputs - old forum post Forum - Published: Cready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on...moreCready24 Joined on 02-08-2008 Posts 3 1.#QNAN on all wired analog inputs I’m configuring a PAC system with 6 analog +/-20mA input modules (SNAP-AIMA-4). Using PAC Manager, I can see the currents on all the wired inputs. All the inputs are sourced by 4-20mA transducers and most are currently wired in. All of the currents displayed in PAC Manager appear to be correct (minus a few minor calibration issues (ie. 3.6mA instead of 4mA when off). The problem is that PAC Control Basic is showing a 1.#QNA...... <less Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Adjusting temperature range on thermocouple Forum - Published: I’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees...moreI’m just working at connecting some thermocouples (Type T) to a SNAP-AITM8 module. When I configure the points as being Type T thermocouples, the temperature values being returned are 3-4 degrees Celsius higher than what the actual temperature is (according to a thermometer). When configuring the points, the temperature range is preset based on the thermocouple chosen and is not adjustable. I’ve played with configuring my Type T thermocouple as a Type S and so forth but I’m still not receiving...... <less Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Upload from the SNAP-PAC-R2 controller Forum - Published: Hi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the...moreHi, I have a SNAP-PAC-R2 controller connected with 2 DI & 1 DO at a site, I need to add another DI module, I don’t have the opto database file[.otg] nor any supporting files, how do I retrieve the backup from the controller? I have tried uploading the strategy from “PAC TERMINAL”, but there is an error while uploading which states " Timeout while connecting to device. Check hardware connection, address, power and jumpers. CODE -10038[ but I’m able to ping the controller IP, and application is r...... <less Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Unable to read max and min points Forum - Published: I’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly...moreI’m putting together an application in vb that uses the Memmap functions. The Opto is an EB1, ENET On reading a min and max analog value, I’m having trouble. I’ve got a grid view that is regularly updating and getting the values of the analog inputs, and I have a button that runs this: [I] Dim intResult, intOffset As Integer Dim sngValue, msngAnalogMinValue As Single Dim mBrain As New OptoSnapIoMemMapXLib.OptoSnapIoMemMapX intOffset = &HF01D4000 + (gclsOpto.ainpSupplyPressure.ModuleNumber * 768...... <less Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
Ethernet 1 and Ethernet 2 Configuration Forum - Published: SO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I...moreSO! I’m using SNAP-PAC-R1s. I have a configuration of Opto A Ethernet 1 connected to a Laptop. Opto A Ethernet 2 connected to Opto B Ethernet 1. Do I need to set Opto A Ethernet 2 to an IP address? I swear I didn’t need to set it and Opto A could communicate with Opto B and send commands to Opto B modules…but when I try to run the strategy, I get an error that it can’t find Opto B. I have a new configuration where I use a switch and my software communicates fine between all, but for design purpo...... <less PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables
PAC Control 101: Communication Handles Forum - Published: What’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485...moreWhat’s a Communication Handle, and when would I want to use one? OVERVIEW: A Communication Handle will allow you to: Communicate with another device via SERIAL connection, like RS-232 or RS-485. This could be an Opto 22 product like our LED dimmer, or just about anything with a 232/485 port, like a GPS receiver. The physical connection can be either on your PAC-R, or PAC-S series controller, or via one of our serial SNAP-SCM- modules on the same rack as a PAC-R or PAC-EB series controller/brain...... <less Ignition launched from Groov accessing Opto22 PAC data tables