Opto Groov Manage API - Set Counter Value
Forum - Published:
I’m working with an Opto Groov controller with a Digital Input with Quadrature module attached to it. I have the feature set to Counter and would like to be able to Set the value of that counter via the...more
Activating Your groov EPIC Processor
Documents - 2312 - Published:
This document comes in the box with your groov EPIC processor (GRV-EPIC-PR1 or GRV-EPIC-PR2). It shows you how to activate your groov EPIC processor with the latest firmware after you have...more
Output sinewave via 0-10v analog output
Forum - Published:
This might be silly, but I wonder, If I create a program in groov pac control that outputs a sine wave 0-10V via one of analog output channel that will run continuously , would I wear the output module or cpu?...
PAC Control Digital Input: Allow Write Capability disabled?
Forum - Published:
Hey all, I’m using a Digital Input channel on a GRV-MM1001 module to monitor for a button press, with the intention of reading the Onlatch from an OPC tag and clearing it after read. When trying to do...more
Version Compatibility?
Forum - Published:
If I have an older controller with a strategy file on it that I want to pull from the controller to my computer, do I need to have my version of PAC Manager match the firmware version or the version of...more
Best Practices for Securing PAC Control Systems?
Forum - Published:
Hi all, I’m currently working on a PAC Project-based setup and was wondering what steps others here take to secure their control systems. We’re using PAC Control and PAC Display in a small industrial...more
During EPIC boot up, GRV-OVMAILP-8 voltage outputs may not be at zero volts
Knowledge Base - KB91176 - Published:
When a groov EPIC unit with a GRV-OVMAILP-8 module is booting up or when the module is hot swapped, any channels configured as a voltage output may output a non-zero voltage for a few seconds.
Any way to restore file
Forum - Published:
I need assistance regarding a SNAP-PAC-R1 controller that has stopped responding through the RS-232 serial port after being disconnected from the power supply for an extended period (+4 years). Issue...more
How toPass Groov view Tags from Siemens Device to PAC to Code
Forum - Published:
Groov view as a web server, and pac in Epic as a Core Controller. In EPIC, I Create Tags Read from such as OPC UA, Modbus Devices, Pac in EPIC…, My question is how could I pass these Tags to Pac in Epic to Code....
Issue with PAC Display not updating tags in real time
Forum - Published:
Hi everyone, I’m working with PAC Display and noticed that some of my tag values aren’t updating in real time—they only refresh when I reopen the screen. The strategy is running fine in PAC Control...more
Access to SNAP-R1 Firmware 10.4
Forum - Published:
We have a fresh out of the package Gen1 SNAP-PAC-R1. When we attempt to update the firmware to the latest version (10.5g) available from the website, the updater fails with an “incompatible hardware...more
Random OptoOPCServer errors and/or PAC Display Runtime crashes
Knowledge Base - KB91057 - Published:
You may experience random errors in OptoOPCServer and/or OPC clients. When using PAC Display Runtime, you may experience random errors in both programs, and PAC Display Runtime may crash with the error...more
Inaccurate status information in PAC Control for I/O units configured for redundant networking
Knowledge Base - KB91042 - Published:
When inspecting I/O units configured for redundant networks in Debug mode in PAC Control Professional, the Address section on the Information tab of the Inspect dialog box may not accurately show the current network status.
URL command to start Flow in Node-Red
Forum - Published:
Hello everyone, I have this Node-Red flow and I want to start it with URL. How can I do it? I try this ULR: https://192.168.12.33/node-red/set_daq_stop; https://192.168.12.33/node-red/cmd/set_daq_stop...more
Case Study: Preventing a Data Center Shutdown
Documents - 2437 - Published:
View in HTML After an HVAC retrofit in 2022, the headquarters of a nationwide bank in Australia encountered an unplanned shutdown of their data center, which was critical to their banking operations...more
Json to excel from one system to another
Forum - Published:
hey , currently I am managing opencore dashboard from machine A and I have installed openrpa in machine 2 . I trigger workflows from machine A which runs on machine B . now the solution or idea I need...more
Ignition access to serial ports
Forum - Published:
I am trying to access the serial ports from Ignition running on the Epic. I have tried both the usb ports AND the serial module on slot 3. image918×879 28.7 KB I only ever get an error about not able to open the port. Any advice?...
Some full-feature groov I/O modules may disrupt communication with groov I/O simple and serial modules
Knowledge Base - KB91168 - Published:
If an affected groov I/O module is inserted in one of the first five slots (positions 0 through 4) of the chassis, groov simple modules in positions 0 through 7 and groov serial modules (only supported...more