The OptoEMU Sensor Energy Monitoring Unit monitors the electrical energy used in your facility and then delivers that data to online software applications, using your existing wired or wireless Ethernet network.
Energy data can also be incorporated into a control system, including the SNAP PAC System and systems communicating via Modbus/TCP or OPC. In addition, data can be sent to common SQL databases.
The OptoEMU Sensor gives you the detailed, real-time data you need to analyze energy consumption, manage use, and reduce energy costs.
|
| 1932 |
|
| 1958 |
OptoEMU Sensor™ Energy Monitoring Units monitor the electrical energy used in your facility and then deliver that data to applications so you can see it, analyze it, and take steps to reduce energy costs.
The OptoEMU Sensor can provide data to web-based or local software services; to control systems based on Opto 22’s PAC Project™ software and Modbus/TCP; to OPC clients; and to standard SQL databases. This Communication Guide shows you how to communicate with the Sensor in all these ways.
NOTE: To install and use the OptoEMU Sensor and see energy data through online software services such as Pulse Energy and eSight, see the OptoEMU Sensor User's Guide. If you are using the Sensor only with these online services, you do not need this Communication Guide.
|
| 2070 |
This data sheet shows how you can find specific ways to reduce energy costs and control energy usage to lower costs.
Using Powerit Solutions Spara technology with your Opto 22 OptoEMU Sensor energy monitoring unit and SNAP PAC System, you can realize significant savings.
The data sheet discusses two ways you can use energy data: Demand Diagnostics and Demand Management.
- Demand Diagnostics analyzes energy usage and identifies potential cost savings.
- Demand Management captures energy cost savings by controlling energy loads based on rules you set. Demand Management also lets you take advantage of utility providers' programs, including Demand Response and Dynamic Pricing.
|
| RM_OptoEMU_FW |
|
| RM_OptoEMU_Sens |
|
| 2026 |
The Energy Monitoring HMI (human-machine interface) for OptoEMU Sensor gives you a simple way to see the energy your facility is using, so you can analyze this detailed data and take steps to reduce energy costs.
The Energy Monitoring HMI displays data from one OptoEMU Sensor (any model).
This Quick Start guide shows you how to install and use the Energy Monitoring HMI.
|
| 1914S |
Automatización y La Red Inteligente (Smart Grid): Gestión de Energía is a white paper in Spanish.
To read this white paper in English, see form 1914.
|
| 1914 |
This white paper looks at the way electricity is produced in the United States today and the vision for a "Smart Grid" in the future.
The paper also discusses specific ways that small and medium-sized industrial and commercial businesses can manage electrical usage and costs today, without waiting for Smart Grid technology.
|
| 1914P |
Automação e a Rede Inteligente (Smart Grid): Gestão de Energia is a white paper in Portuguese.
To read this white paper in English, see form 1914.
|
| 1993 |
This white paper introduces the concept of demand response (DR) in energy management. DR offers an opportunity for industrial and commercial businesses to not just reduce energy costs, but also earn a revenue stream from their use of electrical energy.
The paper briefly discusses how electrical energy is produced and distributed in the United States and then describes four practical steps automation professionals can begin now to take advantage of DR programs in their area.
|
| 1965 |
|
| 1953 |
|
| 1962 |
|
| 1950 |
|
| 2042 |
|
| 1649 |
|
| 2006 |
|
| 1535 |
An analog calibration issue exists for OptoEMU-SNR-3V units with date codes of July 2011 and earlier. This issue only affects customers who are using the product with a "direct connection," that is, measuring power via current transformers (CTs). The calibration issue does not affect those using the product with pulse inputs.
This technical note shows you how to determine whether your unit is affected and how to fix the issue. Use this technical note with the OptoEMU Sensor Analog Calibration File, which contains a command line utility.
|
| 1951 |
OptoEMU Sensor 3V monitors energy usage in your building or facility and sends energy data so you can see it online and use it in building and control systems. You can analyze patterns and identify ways to reduce energy costs.
The OptoEMU Sensor 3V Quick Start Card shows you how to begin using OptoEMU Sensor 3V. For more detailed steps, see the OptoEMU Sensor User's Guide, form 1932.
|
| 1954 |
|