Opto22 MFA/2FA existance? Forum - Published: Was hoping someone in the community out there shares a similar situation - We use a Node-RED dashboard and will most likely move to GroovView in the future, however we are investigating unique logins for...moreWas hoping someone in the community out there shares a similar situation - We use a Node-RED dashboard and will most likely move to GroovView in the future, however we are investigating unique logins for individuals through Opto22 itself. Is MFA/2FA available for Opto22 local user accounts? Is this something that we would have to DIY in our Node-RED dashboard?... <less Inserting timestamp into serial string in Node-RED Forum - Published: I’m relatively new to Node-RED, so this should be a pretty straightforward question. I have an RS-232 line from an old machine feeding into Node-RED through a serial module on my Epic. Everytime the...moreI’m relatively new to Node-RED, so this should be a pretty straightforward question. I have an RS-232 line from an old machine feeding into Node-RED through a serial module on my Epic. Everytime the machine is cycled, a string of data is sent to a Serial In node in my flow, then I’m writing this string to a new line of a .txt file that’s stored on the Epic. The string from the machine contains an inaccurate, non-updating timestamp (there’s no way to reconfigure this on the machine side, it’s lit...... <less Installing node-red-node-serialport (EPIC firmware 3.5) Forum - Published: A customer had issues installing node-red-node-serialport at the latest version (2.0.2 at the time of writing) with groov EPIC firmware 3.5, and unfortunately the NPM packages and their prerequisites are...moreA customer had issues installing node-red-node-serialport at the latest version (2.0.2 at the time of writing) with groov EPIC firmware 3.5, and unfortunately the NPM packages and their prerequisites are out of Opto control, so I dug into it and found a workaround. To get it installed, go to the manage “install nodes” interface from groov Manage Home → Node-RED → Advanced: Node Management, it looks like this… image914×316 14.7 KB Once you’re there put in the module name node-red-node-serialport...... <less Communication errors from I/O on same controller strategy is running on Forum - Published: Attached is a screenshot of the errors I am getting. The strategy is running on a groov epic PR1 defined as M11epic017. It is running firmware version 3.5.1-b.85. any idea why would these errors be...moreAttached is a screenshot of the errors I am getting. The strategy is running on a groov epic PR1 defined as M11epic017. It is running firmware version 3.5.1-b.85. any idea why would these errors be happening on the controller talking to the I/O connected directly to the same chassis? In the chart that is running that references the points that are shown, we grab values from a section of the Int32 & Float scratchpad (also on same controller), write the digital outputs to a different section of th...... <less Accelerating the Industry: 28th Annual ARC Industry Forum Blog - Published: Opto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this...moreOpto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this cutting-edge event where tech enthusiasts and industry professionals gathered to explore the latest in smart manufacturing, digital transformation, and industrial automation, and I’m eager to share the highlights and heartbeats of this remarkable gathering. <less Writing to .txt file using Node-RED. Want to write to a new file name depending on timestamp, etc Forum - Published: I am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the...moreI am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the serial device is cycled (it is an ultrasonic welder), a text string is written to a new line on a .txt file using the Write File node in Node-RED. Is there a way to use Node-RED to conditionally write to a new .txt file depending on a different input, or depending on a part of the text string? Specifi...... <less Same device type, different tag source Forum - Published: I have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that...moreI have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that Groov View page. Essentially a dynamic reference to static tags so I don’t have to build over 200 copies of the same page. Any suggestions?... <less Join the OptoForums community Blog - Published: Get great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good...moreGet great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good reason. The Forums have valuable technical advice, sample code, product feature discussions, and firmware release previews that you can't get anywhere else.The OptoForums community just surpassed 10,000 members! A sincere thank you to all our valuable contributors. And if you're not already a member, now is the time to sign up or sign in with your MyOpto account. You can find the direct link under the Community tab on our website. <less The cybersecurity role of a client or server Blog - Published: Beyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more...moreBeyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more importantly, how can you use that information to strengthen your network security and mitigate insecurities? The best place to start with this topic is to loosely define what makes software act as a server or as a client. But throughout this blog, keep in mind that the two are not mutually exclusive—some devices can be both a server and a client. When playing the role of a server the key trait is that the server device is always listening. <less Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Inserting timestamp into serial string in Node-RED Forum - Published: I’m relatively new to Node-RED, so this should be a pretty straightforward question. I have an RS-232 line from an old machine feeding into Node-RED through a serial module on my Epic. Everytime the...moreI’m relatively new to Node-RED, so this should be a pretty straightforward question. I have an RS-232 line from an old machine feeding into Node-RED through a serial module on my Epic. Everytime the machine is cycled, a string of data is sent to a Serial In node in my flow, then I’m writing this string to a new line of a .txt file that’s stored on the Epic. The string from the machine contains an inaccurate, non-updating timestamp (there’s no way to reconfigure this on the machine side, it’s lit...... <less Installing node-red-node-serialport (EPIC firmware 3.5) Forum - Published: A customer had issues installing node-red-node-serialport at the latest version (2.0.2 at the time of writing) with groov EPIC firmware 3.5, and unfortunately the NPM packages and their prerequisites are...moreA customer had issues installing node-red-node-serialport at the latest version (2.0.2 at the time of writing) with groov EPIC firmware 3.5, and unfortunately the NPM packages and their prerequisites are out of Opto control, so I dug into it and found a workaround. To get it installed, go to the manage “install nodes” interface from groov Manage Home → Node-RED → Advanced: Node Management, it looks like this… image914×316 14.7 KB Once you’re there put in the module name node-red-node-serialport...... <less Communication errors from I/O on same controller strategy is running on Forum - Published: Attached is a screenshot of the errors I am getting. The strategy is running on a groov epic PR1 defined as M11epic017. It is running firmware version 3.5.1-b.85. any idea why would these errors be...moreAttached is a screenshot of the errors I am getting. The strategy is running on a groov epic PR1 defined as M11epic017. It is running firmware version 3.5.1-b.85. any idea why would these errors be happening on the controller talking to the I/O connected directly to the same chassis? In the chart that is running that references the points that are shown, we grab values from a section of the Int32 & Float scratchpad (also on same controller), write the digital outputs to a different section of th...... <less Accelerating the Industry: 28th Annual ARC Industry Forum Blog - Published: Opto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this...moreOpto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this cutting-edge event where tech enthusiasts and industry professionals gathered to explore the latest in smart manufacturing, digital transformation, and industrial automation, and I’m eager to share the highlights and heartbeats of this remarkable gathering. <less Writing to .txt file using Node-RED. Want to write to a new file name depending on timestamp, etc Forum - Published: I am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the...moreI am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the serial device is cycled (it is an ultrasonic welder), a text string is written to a new line on a .txt file using the Write File node in Node-RED. Is there a way to use Node-RED to conditionally write to a new .txt file depending on a different input, or depending on a part of the text string? Specifi...... <less Same device type, different tag source Forum - Published: I have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that...moreI have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that Groov View page. Essentially a dynamic reference to static tags so I don’t have to build over 200 copies of the same page. Any suggestions?... <less Join the OptoForums community Blog - Published: Get great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good...moreGet great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good reason. The Forums have valuable technical advice, sample code, product feature discussions, and firmware release previews that you can't get anywhere else.The OptoForums community just surpassed 10,000 members! A sincere thank you to all our valuable contributors. And if you're not already a member, now is the time to sign up or sign in with your MyOpto account. You can find the direct link under the Community tab on our website. <less The cybersecurity role of a client or server Blog - Published: Beyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more...moreBeyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more importantly, how can you use that information to strengthen your network security and mitigate insecurities? The best place to start with this topic is to loosely define what makes software act as a server or as a client. But throughout this blog, keep in mind that the two are not mutually exclusive—some devices can be both a server and a client. When playing the role of a server the key trait is that the server device is always listening. <less Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Installing node-red-node-serialport (EPIC firmware 3.5) Forum - Published: A customer had issues installing node-red-node-serialport at the latest version (2.0.2 at the time of writing) with groov EPIC firmware 3.5, and unfortunately the NPM packages and their prerequisites are...moreA customer had issues installing node-red-node-serialport at the latest version (2.0.2 at the time of writing) with groov EPIC firmware 3.5, and unfortunately the NPM packages and their prerequisites are out of Opto control, so I dug into it and found a workaround. To get it installed, go to the manage “install nodes” interface from groov Manage Home → Node-RED → Advanced: Node Management, it looks like this… image914×316 14.7 KB Once you’re there put in the module name node-red-node-serialport...... <less Communication errors from I/O on same controller strategy is running on Forum - Published: Attached is a screenshot of the errors I am getting. The strategy is running on a groov epic PR1 defined as M11epic017. It is running firmware version 3.5.1-b.85. any idea why would these errors be...moreAttached is a screenshot of the errors I am getting. The strategy is running on a groov epic PR1 defined as M11epic017. It is running firmware version 3.5.1-b.85. any idea why would these errors be happening on the controller talking to the I/O connected directly to the same chassis? In the chart that is running that references the points that are shown, we grab values from a section of the Int32 & Float scratchpad (also on same controller), write the digital outputs to a different section of th...... <less Accelerating the Industry: 28th Annual ARC Industry Forum Blog - Published: Opto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this...moreOpto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this cutting-edge event where tech enthusiasts and industry professionals gathered to explore the latest in smart manufacturing, digital transformation, and industrial automation, and I’m eager to share the highlights and heartbeats of this remarkable gathering. <less Writing to .txt file using Node-RED. Want to write to a new file name depending on timestamp, etc Forum - Published: I am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the...moreI am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the serial device is cycled (it is an ultrasonic welder), a text string is written to a new line on a .txt file using the Write File node in Node-RED. Is there a way to use Node-RED to conditionally write to a new .txt file depending on a different input, or depending on a part of the text string? Specifi...... <less Same device type, different tag source Forum - Published: I have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that...moreI have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that Groov View page. Essentially a dynamic reference to static tags so I don’t have to build over 200 copies of the same page. Any suggestions?... <less Join the OptoForums community Blog - Published: Get great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good...moreGet great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good reason. The Forums have valuable technical advice, sample code, product feature discussions, and firmware release previews that you can't get anywhere else.The OptoForums community just surpassed 10,000 members! A sincere thank you to all our valuable contributors. And if you're not already a member, now is the time to sign up or sign in with your MyOpto account. You can find the direct link under the Community tab on our website. <less The cybersecurity role of a client or server Blog - Published: Beyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more...moreBeyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more importantly, how can you use that information to strengthen your network security and mitigate insecurities? The best place to start with this topic is to loosely define what makes software act as a server or as a client. But throughout this blog, keep in mind that the two are not mutually exclusive—some devices can be both a server and a client. When playing the role of a server the key trait is that the server device is always listening. <less Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Communication errors from I/O on same controller strategy is running on Forum - Published: Attached is a screenshot of the errors I am getting. The strategy is running on a groov epic PR1 defined as M11epic017. It is running firmware version 3.5.1-b.85. any idea why would these errors be...moreAttached is a screenshot of the errors I am getting. The strategy is running on a groov epic PR1 defined as M11epic017. It is running firmware version 3.5.1-b.85. any idea why would these errors be happening on the controller talking to the I/O connected directly to the same chassis? In the chart that is running that references the points that are shown, we grab values from a section of the Int32 & Float scratchpad (also on same controller), write the digital outputs to a different section of th...... <less Accelerating the Industry: 28th Annual ARC Industry Forum Blog - Published: Opto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this...moreOpto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this cutting-edge event where tech enthusiasts and industry professionals gathered to explore the latest in smart manufacturing, digital transformation, and industrial automation, and I’m eager to share the highlights and heartbeats of this remarkable gathering. <less Writing to .txt file using Node-RED. Want to write to a new file name depending on timestamp, etc Forum - Published: I am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the...moreI am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the serial device is cycled (it is an ultrasonic welder), a text string is written to a new line on a .txt file using the Write File node in Node-RED. Is there a way to use Node-RED to conditionally write to a new .txt file depending on a different input, or depending on a part of the text string? Specifi...... <less Same device type, different tag source Forum - Published: I have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that...moreI have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that Groov View page. Essentially a dynamic reference to static tags so I don’t have to build over 200 copies of the same page. Any suggestions?... <less Join the OptoForums community Blog - Published: Get great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good...moreGet great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good reason. The Forums have valuable technical advice, sample code, product feature discussions, and firmware release previews that you can't get anywhere else.The OptoForums community just surpassed 10,000 members! A sincere thank you to all our valuable contributors. And if you're not already a member, now is the time to sign up or sign in with your MyOpto account. You can find the direct link under the Community tab on our website. <less The cybersecurity role of a client or server Blog - Published: Beyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more...moreBeyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more importantly, how can you use that information to strengthen your network security and mitigate insecurities? The best place to start with this topic is to loosely define what makes software act as a server or as a client. But throughout this blog, keep in mind that the two are not mutually exclusive—some devices can be both a server and a client. When playing the role of a server the key trait is that the server device is always listening. <less Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Accelerating the Industry: 28th Annual ARC Industry Forum Blog - Published: Opto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this...moreOpto 22's Director of Technical Marketing, Dan White, shares his experience from this year's annual ARC event. In its 28th year, the ARC’s Industry Forum did not disappoint. I just returned from this cutting-edge event where tech enthusiasts and industry professionals gathered to explore the latest in smart manufacturing, digital transformation, and industrial automation, and I’m eager to share the highlights and heartbeats of this remarkable gathering. <less Writing to .txt file using Node-RED. Want to write to a new file name depending on timestamp, etc Forum - Published: I am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the...moreI am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the serial device is cycled (it is an ultrasonic welder), a text string is written to a new line on a .txt file using the Write File node in Node-RED. Is there a way to use Node-RED to conditionally write to a new .txt file depending on a different input, or depending on a part of the text string? Specifi...... <less Same device type, different tag source Forum - Published: I have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that...moreI have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that Groov View page. Essentially a dynamic reference to static tags so I don’t have to build over 200 copies of the same page. Any suggestions?... <less Join the OptoForums community Blog - Published: Get great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good...moreGet great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good reason. The Forums have valuable technical advice, sample code, product feature discussions, and firmware release previews that you can't get anywhere else.The OptoForums community just surpassed 10,000 members! A sincere thank you to all our valuable contributors. And if you're not already a member, now is the time to sign up or sign in with your MyOpto account. You can find the direct link under the Community tab on our website. <less The cybersecurity role of a client or server Blog - Published: Beyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more...moreBeyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more importantly, how can you use that information to strengthen your network security and mitigate insecurities? The best place to start with this topic is to loosely define what makes software act as a server or as a client. But throughout this blog, keep in mind that the two are not mutually exclusive—some devices can be both a server and a client. When playing the role of a server the key trait is that the server device is always listening. <less Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Writing to .txt file using Node-RED. Want to write to a new file name depending on timestamp, etc Forum - Published: I am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the...moreI am using a GRV-EPIC-PR2 with serial module GRV-CSERI-4. I have an RS-232 stream connecting a serial device to the serial module and have a connection configured in Node-RED so that every time the serial device is cycled (it is an ultrasonic welder), a text string is written to a new line on a .txt file using the Write File node in Node-RED. Is there a way to use Node-RED to conditionally write to a new .txt file depending on a different input, or depending on a part of the text string? Specifi...... <less Same device type, different tag source Forum - Published: I have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that...moreI have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that Groov View page. Essentially a dynamic reference to static tags so I don’t have to build over 200 copies of the same page. Any suggestions?... <less Join the OptoForums community Blog - Published: Get great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good...moreGet great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good reason. The Forums have valuable technical advice, sample code, product feature discussions, and firmware release previews that you can't get anywhere else.The OptoForums community just surpassed 10,000 members! A sincere thank you to all our valuable contributors. And if you're not already a member, now is the time to sign up or sign in with your MyOpto account. You can find the direct link under the Community tab on our website. <less The cybersecurity role of a client or server Blog - Published: Beyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more...moreBeyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more importantly, how can you use that information to strengthen your network security and mitigate insecurities? The best place to start with this topic is to loosely define what makes software act as a server or as a client. But throughout this blog, keep in mind that the two are not mutually exclusive—some devices can be both a server and a client. When playing the role of a server the key trait is that the server device is always listening. <less Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Same device type, different tag source Forum - Published: I have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that...moreI have an application where I have over 200 of the same device type and I’d like to create a single page that I can pass the device reference and have it read the tags from the device to display on that Groov View page. Essentially a dynamic reference to static tags so I don’t have to build over 200 copies of the same page. Any suggestions?... <less Join the OptoForums community Blog - Published: Get great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good...moreGet great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good reason. The Forums have valuable technical advice, sample code, product feature discussions, and firmware release previews that you can't get anywhere else.The OptoForums community just surpassed 10,000 members! A sincere thank you to all our valuable contributors. And if you're not already a member, now is the time to sign up or sign in with your MyOpto account. You can find the direct link under the Community tab on our website. <less The cybersecurity role of a client or server Blog - Published: Beyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more...moreBeyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more importantly, how can you use that information to strengthen your network security and mitigate insecurities? The best place to start with this topic is to loosely define what makes software act as a server or as a client. But throughout this blog, keep in mind that the two are not mutually exclusive—some devices can be both a server and a client. When playing the role of a server the key trait is that the server device is always listening. <less Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Join the OptoForums community Blog - Published: Get great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good...moreGet great resources and tips from experienced Opto 22 product users—and help other users with your insights. You’ll see the OptoForums mentioned here on the blog from time to time, and that's for good reason. The Forums have valuable technical advice, sample code, product feature discussions, and firmware release previews that you can't get anywhere else.The OptoForums community just surpassed 10,000 members! A sincere thank you to all our valuable contributors. And if you're not already a member, now is the time to sign up or sign in with your MyOpto account. You can find the direct link under the Community tab on our website. <less The cybersecurity role of a client or server Blog - Published: Beyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more...moreBeyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more importantly, how can you use that information to strengthen your network security and mitigate insecurities? The best place to start with this topic is to loosely define what makes software act as a server or as a client. But throughout this blog, keep in mind that the two are not mutually exclusive—some devices can be both a server and a client. When playing the role of a server the key trait is that the server device is always listening. <less Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
The cybersecurity role of a client or server Blog - Published: Beyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more...moreBeyond data transactions, understanding the relationship between clients and servers plays a significant role in cybersecurity. What makes a device fill the role of a server or client? And, more importantly, how can you use that information to strengthen your network security and mitigate insecurities? The best place to start with this topic is to loosely define what makes software act as a server or as a client. But throughout this blog, keep in mind that the two are not mutually exclusive—some devices can be both a server and a client. When playing the role of a server the key trait is that the server device is always listening. <less Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Codesys Automation Server Forum - Published: We are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the...moreWe are looking to use the Codesys automation server to server as a code repository for all of our epics. (~30) Looking at the documentation and from our experimentation we will need to install the CODESYS Edge Gateway on a computer with direct IP access to the PLC. Codesys has a gateway “Codesys for Linux” that we tried to install on the EPIC. We tried to install all of the linux packages available and they all failed with errors in image attached. Is running the automation server gatewa...... <less How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
How to give data in hex to integer from string Forum - Published: sir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in...moresir i just want to give data to integer 64 from a string please tell how can i give the string data to integer 64 just as is shown in example my hex string data =0AB12985FFDC67 now i want this value in integer 64 as follow intger64 = 0x0AB12985FFDC67 now to how can convert hex string data to integer64 and vice versa... <less PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
PAC Manager may not accept 12-digit IP address and subnet mask for ETHERNET 2 Interface Knowledge Base - KB90853 - Published: 2/5/2024 On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface.On the Status Write page of the Inspect window of PAC Manager, you may not be able to enter an IP address or subnet mask that contains 12 digits (3 digits in all 4 octets, such as 255.255.255.255) for the ETHERNET 2 Interface. <less How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
How to remove follwing errors Forum - Published: i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero...i am getting this errors will you help me to resolve this errors -98 Boot ID from I/O unit doesn’t match the controller’s stored value performing full config. -15 Cannot divide by zero... <less OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
OPENSSL Signed Certficate Not working Forum - Published: First time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I...moreFirst time posting after attending training and I am trying to apply training to our environment. Right now I have seat on the struggle bus. I am trying to sign the SSL cert with a CA that I installed. 1 I spun up an EC2 instance of Ubuntu and 2 Using OpenSSL installed and created the Certifcate Authority 3. After much googling and watching you tube I was able to sign the CSR and upload it to the groove 4. The Certificate shows that cert was signed by TendedBar Root CA and uploaded to ...... <less Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Groov RIO locale and database issues Forum - Published: I’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return...moreI’ve started to port one of my applications to the groov RIO. It’s a linux based application that uses a Postgres database for its storage. Whenever I run the postgresql-setup initdb, it would return [FAILED]. Digging into this, I tried to replicate what the script was doing by hand and ran initdb directly, and it gave me the error: initdb: invalid locale settings; check LANG and LC_* environment variables All of those variables are set to either en_US.utf8 or en_US.UTF-8, but running locale sta...... <less My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
My Opto22 Library doesn't appear to have version 3.5.17.10 Forum - Published: Hi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in...moreHi folks, I’m brand new to the hard and software and I’m trying to update my device in CODESYS, as the version of my GRV-EPIC-PR1 is 3.5.17.10. I’ve got the opto22 library installed, i’m running in 32bit mode but all I see to update my device is version 3.5.18.40 even with all versions and outdated versions selected. Does anyone have any ideas for me? Thanks... <less Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Elevate your OT data securely to the cloud Blog - Published: Watch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition...moreWatch how easy it is to securely connect real-world, OT data to Ignition Cloud Edition. Good news! Our friends at Inductive Automation recently made all the presentations from the 2023 Ignition Community Conference available for public viewing. If you weren't able to join us last September in Folsom, California, then now's your chance to see one of the most attended sessions of the conference. In a fast-paced 35-minute demo, Opto 22's VP of Product Strategy, Benson Hougland, walks you through how to use groov EPIC, Ignition Edge, and Ignition Cloud Edition to quickly create scalable, high-performance, cybersecure architectures for democratizing your OT system’s data: Elevate your OT Data Securely to the Cloud. <less Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Where to see groov in action in 2024 Blog - Published: Visit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto...moreVisit Opto 22's Events page to see where you can find Opto engineers demonstrating groov products in 2024. We're already a month into the new year and our calendar of events is filling up quickly. Opto 22 engineers, sales and marketing staff will be in attendance at various trade shows, conferences and participating in virtual webinars throughout the year. Take a look at what's available online or in your area and plan to join us at one or more of these industry events. You'll have several opportunities to see live demos of groov EPIC and groov RIO. Here's what's on the schedule so far. <less Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Is it possible to add a PAC-R1 as remote I/O in a codesys strategy running on a PR1? Forum - Published: If so, is there any documentation on how to handle this or could someone walk me through the process?...If so, is there any documentation on how to handle this or could someone walk me through the process?... <less Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Cannot log into groov Admin on groov Box products with usernames that contain spaces Knowledge Base - KB90841 - Published: 1/31/2024 You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space.You may encounter an “invalid character” error message when attempting to log into groov Admin on groov Box products if your username contains a space. <less Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Deleted GRV-R7-I1VAPM-3 may not be properly removed from a PAC Control strategy Knowledge Base - KB90711 - Published: 1/30/2024 When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash.When deleting a groov RIO energy monitoring unit (EMU; GRV-R7-I1VAPM-3) from a PAC Control strategy, it may continue to appear in the Strategy Tree. If you attempt to open the deleted groov RIO EMU from the Strategy Tree, PAC Control may crash. <less Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Jetty Version on groov AR1 Forum - Published: What version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty...moreWhat version of Jetty is on the current AR1 (groov Box) release? I have a customer with a NodeRed application running on an AR1 . Their IT department has run a security scan and it says the Jetty version 6.1.24 should be updated. A quick search on Jetty Versions shows version 6’s status as ‘antique’, and more current versions are 9, 10, 11, 12. The AR1 posts messages on port 443 to a Cloud application so it has some exposure to the internet. Do you think an update to the AR1 is necessary?... <less Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Can I use an RIO MM1001 to natively measure natural gas flow through pulse output? Forum - Published: Hello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or...moreHello all! I want to measure the output of a rotary gas flow meter, and I am wondering if I can simply run my output wires into channel 1 of the GRV-R7-MM1001-10? Or if I will need a convertor or something in between? This is the pinout of my rotary flow meter: And channel 1 on the RIO module says it supports “Pulse Measurement”. Thank you! Please let me know if I can provide any further detail.... <less Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Are the 4-channel SNAP digital input cards interchangeable? Forum - Published: Good morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I...moreGood morning, We’ve been using the standard SNAP-IDC5 input card to “count” pulse signals from a water flow paddlewheel sensor to calculate the flow (at fairly high speed, e.g. 93 pulses = 1 Liter). I just noticed there is a similar SNAP-IDC5-FAST-A card that seems might be more suited for the application. Without changing our PAC strategy (would require version update), would the strategy still correctly detect and calculate the water flow? (I’m hoping our same software version would still wo...... <less Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items
Display CODESYS string variable in Groov View Forum - Published: I have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I...moreI have a CODESYS structured text STRING-type variable foo. I want to display it in Groov View. When I go find it in Groov View Build mode’s Gadget Pallette > Tags list, I see foo : STRING : R/W. When I click on the other variables (INT16s, Booleans, Floats), I see a list of available gadgets that I can drag into the preview space. However, when I click on foo, I don’t get any options. I’ve also tried creating a Text Area gadget from the Gadgets menu, but when I select my tag in the Data Source m...... <less « PreviousPage 5 of 356Next » Show 25 Items Show All Items Show 10 Items Show 25 Items Show 50 Items Show 100 Items